DFT-110 SSI Technologies Inc, DFT-110 Datasheet

SENSOR DRUM GAUGE 55GALLON LCD

DFT-110

Manufacturer Part Number
DFT-110
Description
SENSOR DRUM GAUGE 55GALLON LCD
Manufacturer
SSI Technologies Inc
Series
Digital Fluid-Trac™r
Type
Liquidr
Datasheet

Specifications of DFT-110

Output Configuration
LCD Display
Mounting Type
Male 2" (50.8mm) NPT
Material - Housing & Prism
-
Operating Temperature
0°C ~ 50°C
Voltage Rating
-
Minimum Liquid Specific Gravity
-
Switch Actuation Level
-
Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
734-1162
DFT-100
DFT-100-R
Product Description
Digital Fluid-Trac™ Model DFT-110 multi unit drum
level gauge is a cost competitive non-contact liquid
level drum gauge.
designed for usage on ANSI MH2-2004 vertical drums
(≤ 32 inch depths). The DFT-110 drum gauge allows
the user to easily select between the following vertical
drum settings:
SSI TECHNOLOGIES, INC.
Controls Division
2643 W. Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500
Fax: (608) 758-2491
www.ssitechnologies.com
Low Level
Warning
Digital Fluid-Trac™ (DFT-110) Multi-Unit Drum Gauge
15 gallon
30 gallon
55 gallon
57 liter
114 liter
208 liter
SSI Technologies – Application Note DT-AN5
The DFT-110 drum gauge was
Press and release
Refresh/Select to update the
level reading and select
display units
Product Overview
Page 1
Product Features
The Digital Fluid-Trac™ DFT-110 drum level gauge is
NOT intended for use with gasoline.
SSI can customize the drum level gauge for other sizes
for large volume OEM orders.
Contact SSI Technologies at (608) 758-1500.
Multiple Selectable Units: 15, 30, 55 gallons
or 57, 114, 208 liters
Resolution: +/- 0.5 gallon or +/- 1 liter
Accuracy: +/-2% of full scale volume
Automatic Shutoff To Prolong Battery Life
NEMA 4 Packaging
Static
Consumption Calculations: The static level
reading
calculations – i.e. daily or weekly consumption.
Low Level Warning Light: A red LED will
flash once every second when the volume is at
10% or below the maximum volume.
Easy to install: Digital Fluid-Trac™ DFT-110
has no components to protrude into the drum.
Standard: Fits 2” NPT or ¾” NPS opening
More Reliable: No components to chemically
corrode inside liquid media.
Chemical compatibility: Digital Fluid-Trac™
DFT-110 drum gauge works with a wide
variety of media such as water, waste water,
motor oil, hydraulic fluid and diesel fuel.
can
Display
be
Copyright April 21, 2009
SSI Technologies Inc.
used
All Rights Reserved
Useful
Revision 1
for
for
manual
RoHS
Usage
rate

Related parts for DFT-110

DFT-110 Summary of contents

Page 1

... The DFT-110 drum gauge was designed for usage on ANSI MH2-2004 vertical drums (≤ 32 inch depths). The DFT-110 drum gauge allows the user to easily select between the following vertical drum settings: 15 gallon • ...

Page 2

... The distance from the Digital Fluid-Trac’s sensor to the liquid is calculated based on the speed of sound. The Digital Fluid-Trac™ DFT-110 has a LCD which displays the liquid level pictorially as well as in gallon (or liter) units. The display shows the level reading from the last time the Refresh/Select button was pressed ...

Page 3

... Testing With The DFT-110 a) After you have selected the proper units and drum size for your application, Press and release the Refresh/Select button. b) The DFT-110’s back-light is illuminated and 8.8.8. is displayed for 4 seconds to indicate the unit is in test mode. c) The DFT-110 continuously monitors the media in the vertical drum for 7 seconds and then displays this liquid level ...

Page 4

... The 55 gallon drum gauge mounts on top of the drum with a standard 2” NPT thread connector. A ¾ inch NPS threaded adapter is included with each Digital Fluid-Trac™ Model DFT-110 so either bung opening can be used on the drums. ™ When using the Digital Fluid-Trac keep the mounting perpendicular to the liquid level by storing the drums in an upright position ...

Related keywords