Specifications of LA1KN11

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Rohs Compliant
No
For Use With
K-Line Contactors
IEC Type Industrial Control Relays
TeSys D-Line, K-Line, and SK-Line
Class 8501
CONTENTS
Description
Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
TeSys D-Line Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
TeSys D-Line Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TeSys D-Line Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
K-Line Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
K-Line Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
K-Line Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SK-Line Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Schneider Electric Brands
Long Distance Control Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Related parts for LA1KN11

LA1KN11 Summary of contents

Page 1

... IEC Type Industrial Control Relays TeSys D-Line, K-Line, and SK-Line Class 8501 CONTENTS Description Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 TeSys D-Line Ordering Information TeSys D-Line Dimensions TeSys D-Line Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 K-Line Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 K-Line Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 K-Line Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SK-Line Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Long Distance Control Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Page ...

Page 2

... These 600 volt relays are approved for use around the world. TeSys D-Line relays are usually mounted DIN 3 track, but can also be mounted directly to a panel. The fixed contacts in these relays have a NEMA A600 and Q600 ratings, in addition to the standard IEC ratings, making them suitable for use in most any control circuit ...

Page 3

TeSys Ordering Information CAD32 LAD8N20 CAD50 LAD8N11 LAD8N02 CAD323 CAD503 04/01 20 LADN 3 LADN113 LADN023 LADN 3 LADC223 3, LADR 3, LADS 3 LADT © 2001 Schneider Electric All Rights Reserved TeSys Ordering Information LADN20 LADN11 LADN02 LADN , ...

Page 4

... Volts Code Grounding terminal points (2 terminals jumpered together; see diagram on page 8). Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils. Add proper voltage code to end of catalog number. Includes 1 N/O and 1 N/C overlapping contact. For ring terminal configuration add “6” before coil voltage suffix. For example CAD32B7 becomes CAD326B7. ...

Page 5

Time Delay Auxiliary Contact Blocks Number and Type of Contacts 1 N/C and 1 N/O LADT (Lockout Cover, See page 7) With extended scale from 0.1 to 0.6 s. With switching time ± between opening ...

Page 6

TeSys Ordering Information Cabling Accessory Description Mounting Adaptor For adapting existing wiring to a new product Electronic Serial Timer Modules Mounted using adaptor LAD4BB ordered separately, see listing above. On-delay Type Operational Voltage 24 to 250 Vac/Vdc Off-delay ...

Page 7

... Accessories (to be ordered separately) For Connection Description For Marking Sheet of 64 self-adhesive blank labels Sheet of 112 self-adhesive blank labels Strips of blank, self-adhesive labels for printing by plotter (4 sets of 5 strips) “SIS Label” label creation software for labels LAD-21 and 22 For Protection ...

Page 8

... TeSys Terminal Configurations Control Relays Instantaneous 5 N/O CAD50 Instantaneous Auxiliary Contact Blocks 1 N N/C LADN11 The figures in brackets are for the device mounted on the RH side of the relay N/C LADN22 With Dust and Damp Protected Contacts 2 N N/C Including 1 N N/C ...

Page 9

TeSys Mounting Dimensions CAD (Vac Coil) c 0.49 12.5 c1 (LAD- CAD - 50 b 3.03 (77) c without cover or add-on blocks 3.31 (84) with cover, without add-on blocks 3.39 (86) c1 with LADN or C ...

Page 10

Tesys Application Data TeSys Application Data Type Conforming to IEC 60947-1-1 Overvoltage category III Rated Insulation Voltage (Ui) and degree of pollution 3 Conforming to UL, CSA Rated Impulse Withstand Voltage (Uimp) Conforming to IEC 60947-1-1 Separation of Electrical Circuits ...

Page 11

... The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. For information on the listed warranty offered on this product, refer to the Square D terms and conditions of sale found in the Square D Digest ...

Page 12

... The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. For information on the listed warranty offered on this product, refer to the Square D terms and conditions of sale found in the Square D Digest ...

Page 13

... Wide range coil (70 to 130% Uc), suppressor fitted as standard. - Mounting DIN3 track or 4 screw direct mounting. - Screws in open “ready-to-tighten” position. DC CA4KN405 Application Data . . . . . . . . . . . 17 Dimensions Contact Configuration Complete catalog number by adding proper voltage code from page 14. Accessories . . . . . . . . . . . 14-15 04/01 Contact Configuration Type of Termination Consumption N/O 4 ...

Page 14

... LA1KN313 0.10 (0.045) LA1KN223 0.10 (0.045) LA1KN133 0.10 (0.045) LA1KN043 0.10 (0.045) LA1KN207 0.10 (0.045) LA1KN027 0.10 (0.045) LA1KN117 0.10 (0.045) LA1KN407 0.10 (0.045) LA1KN317 0.10 (0.045) LA1KN227 0.10 (0.045) LA1KN137 0.10 (0.045) LA1KN047 0.10 (0.045) Catalog Number LA2KT2E ...

Page 15

Z Description Mounting Plates for Fixing Marker Holder Clip-in Markers LA9D973 Suppressor Modules Incorporating LED Indicator Protection by limitation of the transient voltage maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1 ...

Page 16

... On AM1DP200 or AM1DE200 Track (35 mm DIN3) 2.24 57 LA2KT Electronic Time Delay Contact Blocks 1.34 1 CA2, CA3, CA4K Control Relays 4 N N/C LA1K Instantaneous Auxiliary Contact Blocks For CA2, CA3, CA4K 2 N/O 2 N N/C LA2KT Electronic time Delay Contact Blocks ...

Page 17

... The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. For information on the listed warranty offered on this product, refer to the Square D terms and conditions of sale found in the Square D Digest ...

Page 18

... The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life. For information on the listed warranty offered on this product, refer to the Square D terms and conditions of sale found in the Square D Digest ...

Page 19

... Dampens the voltage spike that may occur when the relay coil is de-energized. The spike may adversely affect solid state equipment near the relay. The transient suppressor module snaps into a cavity located in the side of the relay. These modules can be used with CA2SK and CA3SK relays. ...

Page 20

... A600 480 15 7200 600 12 7200 Approximate dimensions Contact Configurations Relays 2 N/O 1 N/O and 1 N/C 20 CA2 IEC337-1, 947-1, 947- 63-140, VDE0660, BS4794 UL Listed File E164353 CCN NKCR, CSA File LR12721 Class 3211 03, SEMKO, SEV, DEMKO, CE °F (° 131 (-20 to 55) AWG Two #20 (0.75) to #16 (1.5) ...

Page 21

... EN50035 & NF C63-018 9080MH379 9080MH439 2 AM1DE200 AM1ED200 mm inches AM1DP200 9080MH82 1 DZ5MB201 AB1AB8M35 100 mm inches © 2001 Schneider Electric All Rights Reserved Accessories Catalog Number Weight lb Std. k Length (kg) Pack 2 78.74" AM1ED200 10 (1.31) 2 78.74" AM1DE200 10 (0.90) 1 78.74" AM1DP200 10 (0 ...

Page 22

... K-Line and SK-Line Accessories Clip-in Marker Strips 10 Identical Numbers (or symbols) AB1R Sold in Lots of 25 Identical Strips Unit Weight: 2g Reference of Marking 10-number tag strip Blank AB1RV 1 AB1R1 2 AB1R2 3 AB1R3 4 AB1R4 5 AB1R5 6 AB1R6 7 AB1R7 8 AB1R8 9 AB1R9 0 AB1R0 + AB1R12 _ AB1R13 Marking Components Holder for 6 Markers ...

Page 23

In order to make the correct choice of protective treatment, two points should be remembered: 1. The prevailing climate of the country is never the only criterion. 2. Only the ambient conditions in the immediate vicinity of the equipment need ...

Page 24

Long Distance Control Data Lone Distance Control Data Voltage Drop Caused by the Inrush Current When the operating coil of a relay is energized, the inrush current produces a voltage drop in the control supply cable caused by the resistance ...

Page 25

Voltage Drop Caused by the Inrush Current (continued) What cable c.s.a. is required for the control circuit of an CAD50G7 relay, operated from a distance of 500 meters. CAD50G7, voltage 120 V, 60 Hz: inrush power: 70 VA. On the ...

Page 26

... When the control contact of a relay is opened the cable capacitance is effectively in series with the coil of the electromagnet. This capacitance can cause a residual current to be maintained in the coil, with the risk that the relay will remain closed. This only applies to relays operating on an a.c. supply. This phenomenon is aggravated by: ...

Page 27

Residual Current in the Coil due to Cable Capacitance (continued) These graphs are for a capacitance, between conductors, of 0.2 F/km. They make it possible to determine whether there is a risk of the contactor remaining closed due to the ...

Page 28

... Square D Company Schneider Canada Inc. 8001 Highway 64 East 19 Waterman Avenue, Knightdale, NC 27545 M4B 1 Y2 1-888-SquareD Toronto, Ontario (1-888-778-2733) 1-800-565-6699 www.SquareD.com www.schneider-electric.ca © Catalog No. 8501CT0101 April 2001 2001 Schneider Electric All Rights Reserved ...

Related keywords