13M2844

 

RXZE2S108M

Manufacturer Part NumberRXZE2S108M
Description13M2844
ManufacturerSQUARE D
SeriesRXZ
RXZE2S108M datasheets

Availability: By request

International delivery:

Warranty: 60 days

Shipping & payment terms

Added to cart

 

Specifications of RXZE2S108M

Socket MountingDIN RailCurrent Rating12A
Socket TerminalsScrewVoltage Rating300V
FeaturesSeparate Contact Arrangement, Box Lug ConnectorRohs CompliantYes
For Use WithRXM 2xxx Relays  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
Page 10/46

Download datasheet (6Mb)Embed
PrevNext
General Purpose Relays
®
Square D
Alternating Plug-In Relays
8501KA alternating relay is designed to minimize pump and motor wear by equalizing run time between parallel
New!
components in a multi-pump system.
The relay is controlled by an external control switch. The switch may be any type of contact closure; for example the
contacts of a timing relay or the closure of a float switch. The 8501KA relay also has a toggle switch that allows the
operator to lock one side of the duplex system in the “on” position.
12 amp Resistive Rating
SPDT or DPDT
Toggle switch for load control
LED Load Indicators
Table 23.38: Type KA — Alternating Relay
Table 23.39: Relay Availability
Type
Voltage Code
8501KA81•••
8501KA82•••
8501KA112•••
8501KA112A•••
Table 23.40: Contact Ratings
Type
8501KA81•••
Table 23.41: Alternating Functions
Diagram
Alternate
A, C & D
Lock 1
Lock 2
Alternate
Lock 1
B
Lock 2
The cross wired option allows extra system load capacity through simultaneous operation of both motors when needed (LA and LB energize
simultaneously when both S1 and S2 are closed–relay contacts are not isolated)
Input voltage must applied at all times for proper alternation. Use of a solid state control switch for S1 or S2 may not initiate alternation corredtly.
ALL
S1 or S2 voltage must be from the same supply as the unit’s input voltage (see wiring diagrams). Loss of input voltage resets the unit; LA becomes
the lead load for the next operation.
Wiring Diagrams and Dimensions
. A
···
8501KA81
Socket = 8501NR51 or NR52
. B
···
8501KA82
Socket = 8501NR51 or NR52
Approvals
23-10
Horsepower Rated
AC and DC Control
UL Listed w/ Square D Socket
Rohs Compliant
Contact
Input Voltage
Options
Arrangement
AC & DC
SPDT
LED + Toggle
AC & DC
DPDT
LED + Toggle + Cross Wired
AC & DC
DPDT (N.C.)
LED + Toggle
AC & DC
DPDT (N.O.)
LED + Toggle
AC & DC Voltage
AC Voltage
12
24
120
240
V36
V14
V20
V24
S
S
S
S
AC
Resistive
AC Volts
HP
Pilot Duty
DC Volts
Amperes
120
12
1/3
30
240
12
1/2
B300
Toggle Switch Position
Detail
S1 = Control Switch 1
Closing S1 alternates the loads between LA and LB.
LA is ON and LB is OFF. S1 is not used in this mode.
LA is OFF and LB is ON. S1 is not used in this mode.
Closing S1 alternates the loads between LA an dLB. S2 will only control LA.
S1 will control LA and S2 will control LB
S1 will control LB and S2 will control LA.
. C
···
8501KA112
Socket = 8501NR61 or NR62
. D
···
8501KA112A
Socket = 8501NR61 or NR62
File
E78351
E78351
Class
NLDX
NLDX2
Discount
CP2
Schedule
8501KA
Refer to Catalog 8501CT9401
www.schneider-electric.us
Type
$ Price
8501KA81•••
95.00
8501KA82•••
95.00
8501KA112•••
95.00
8501KA112A•••
95.00
Note: AC Voltage is 50/60 Hz
“S” items have a 2 week lead time and no minimum order
requirement. All other part numbers require a minimum order
quantity of 100 and have a lead-time of 18 weeks.
DC
Resistive
Amperes
12
S2 = Control Switch 2
LA = Load 1
LB = Load 2
File
242675
IEC 61810-1
Class
3211-07
© 2009 Schneider Electric
All Rights Reserved