- Components/
- Relays/
- Accessories/
RXZE2S108M
RXZE2S108M | |
|---|---|
| Manufacturer Part Number | RXZE2S108M |
| Description | 13M2844 |
| Manufacturer | SQUARE D |
| Series | RXZ |
| RXZE2S108M datasheets |
|
Availability: By request
International delivery:
Warranty: 60 days
×
- We provide standard 60-days warranty for all parts. If warranty differs we always mention it beforehand. In case of return we cover shipping costs.
- If you still have any questions - please contact us
×
Shipping terms
- Standard delivery time differs from 5-8 business days if the supplier is a local one to 12-14 days if the suplier is from overseas. If delivery time differs it's always mentioned in our quotation.
- We ship worldwide using main international couriers like FedEx, DHL, UPS, TNT, EMS. We can also use client's freight account. Other shipping methods can be discussed. We do best to meet your needs!
Payment terms
- For new client payment term is payment in advance. At this moment we accept 3 payment methods: wire transfer, PayPal and Western Union. Credit card payment is under constrution and will be introduced soon. Escrow service is acceptable. Net terms for regular customers is not a problem. Working with us is totally safe for you.
- If you still have any questions - please contact us
Specifications of RXZE2S108M | |||
|---|---|---|---|
| Socket Mounting | DIN Rail | Current Rating | 12A |
| Socket Terminals | Screw | Voltage Rating | 300V |
| Features | Separate Contact Arrangement, Box Lug Connector | Rohs Compliant | Yes |
| For Use With | RXM 2xxx Relays | ||
PrevNext
Industrial Relays
www.schneider-electric.us
®
TeSys
D IEC Style Relays
These 600 volt relays are approved for use around the world. TeSys D relays are usually mounted on 35 mm DIN 3
track, but can also be mounted directly to a panel. The fixed contacts in these relays have a NEMA A600 and Q600
ratings, in addition to the standard IEC ratings, making them suitable for use in most any control circuit. Low
consumption versions of this relay are available for use with low level DC signals from a computer or a PLC. Adder
decks can be added to a basic five pole relay to make it up to an 11 pole relay. The serrated silver-nickel contacts with
wiping action provide excellent reliability in 12 or 24 volt control circuits. Special auxiliary contacts are available for
switching low power down to 5 volts at 10 mA. Timer and mechanical latch attachments are available.
Table 23.66: Instantaneous Control Relays
CAD32
Terminal Type
Screw Clamp
Spring Terminal
Ring Tongue
a
Add the proper voltage code from Table 23.69 to the end of catalog number (for example, CAD50B7).
Table 23.67: Instantaneous Auxiliary Contact Blocks (for use in normal operation environments)
Maximum Number per Device
Number of
Contacts
Front
CAD503
2
4 b
CAD323
4 b
b
Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.
c
Includes 1 N.O. and 1 N.C. overlapping contact.
Table 23.68: Instantaneous Auxiliary Contacts with Dust and Damp Protected Contacts
(for use in particularly harsh industrial environments)
Approvals:
Maximum Number
Number
per Device
of Contacts
File
E164353
CCN
NKCR
Front Mounting
2
File
LR43364
4 e
Class
3211 03
d
Grounding terminal points (2 terminals jumpered together; see diagram on page 8 of Catalog 8501CT0101).
e
Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.
Table 23.69: Coil Voltage Codes
AC 50/60 Hz Coil (for additional voltage code options see page 7 of Catalog 8501CT0101).
Volts
12
Code
J7
DC Coil (coils have built in suppression as standard)
Volts
12
Code
JD
DC Low Consumption Coil (coils have built in suppression as standard)
Volts
5
Code
AL
f
Add the proper voltage code to the end of catalog number.
For replacement AC coils, see page 18-16. DC coils are not replaceable.
© 2009 Schneider Electric
All Rights Reserved
Contact Composition
Normally Open
Normally Closed
Number of Contacts
5
5
3
5
5
3
5
5
5
3
Contact Composition
Clip-on Mounting
Normally Open
Termination Type
Left Side Only
2
Screw Clamp
1
0
1
—
2
Spring Terminal
1
0
2
1
—
Not for
Screw Clamp
1
DC devices
0
4
3
Screw Clamp
2
1
0
1
—
4
3
Spring Terminal
2
1
0
Screw Clamp
2 c
1
—
2 c
Spring Terminal
Contact Composition
Sealed
d
2
—
—
1
—
2
—
2
—
2
2
—
—
1
2
—
—
f
24
48
120
208
240
B7
E7
G7
LE7
U7
24
36
48
60
72
BD
CD
ED
ND
SD
12
24
48
72
JL
BL
EL
SL
Discount
I12
Schedule
Refer to Catalog 8501CT0101
$ Price
Catalog Number
DC or Low
AC Coil
Consumption Coil
0
CAD50a
62.00
2
CAD32a
62.00
0
CAD503a
62.00
2
CAD323a
62.00
0
CAD506a
62.00
2
CAD326a
62.00
Normally Closed
Catalog Number
0
LADN20
1
LADN11
2
LADN02
0
LADN203
1
LADN113
2
LADN023
0
LAD8N20
1
LAD8N11
2
LAD8N02
0
LADN40
1
LADN31
2
LADN22
3
LADN13
4
LADN04
0
LADN403
1
LADN313
2
LADN223
3
LADN133
4
LADN043
2 c
LADC22
2 c
LADC223
Catalog Number
Normal
—
—
LA1DX20
—
—
LA1DX02
—
—
LA1DY20
2
—
LA1DZ40
1
1
LA1DZ31
277
480
600
W7
T7
X7
110
125
220
250
FD
GD
MD
UD
CAD
110.00
110.00
110.00
110.00
110.00
110.00
$ Price
20.70
20.70
20.70
20.70
20.70
20.70
20.70
20.70
20.70
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
$ Price
65.00
65.00
77.00
82.00
82.00
440
RD
23-15
Related parts for RXZE2S108M | |||
|---|---|---|---|
| Part Number | Description | Manufacturer | Datasheet |
|
|
13M2845 | SQUARE D |
|
|
|
13M2846 | SQUARE D |
|
|
|
RELAY SOCKET 300VAC 12A T-R | SQUARE D | |
|
|
13M2840 | SQUARE D |
|
|
|
13M2841 | SQUARE D |
|
|
|
13M2842 | SQUARE D |
|
|
|
13M2843 | SQUARE D |
|
|
|
SQUARE HEAD BOLT W/NUT | THOMAS & BETTS | |
|
|
SQUARE NUT | THOMAS & BETTS | |
|
|
SQUARE WASHER | THOMAS & BETTS | |
|
|
FUSE SWITCH | SQUARE D | |
|
|
100A INTERIOR BARIER FOR HD SWITCH | SQUARE D | |
|
|
CB ACCESSORY, COMBINATION BUSBAR | SQUARE D | |
|
|
LIMIT SWITCH LATCH L | SQUARE D | |
|
|
CB ACCESSORY, UNDERVOLTAGE TRIP 48V DC | SQUARE D |
|

