13M2844

 

RXZE2S108M

Manufacturer Part NumberRXZE2S108M
Description13M2844
ManufacturerSQUARE D
SeriesRXZ
RXZE2S108M datasheets

Availability: By request

International delivery:

Warranty: 60 days

Shipping & payment terms

Added to cart

 

Specifications of RXZE2S108M

Socket MountingDIN RailCurrent Rating12A
Socket TerminalsScrewVoltage Rating300V
FeaturesSeparate Contact Arrangement, Box Lug ConnectorRohs CompliantYes
For Use WithRXM 2xxx Relays  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
Page 16/46

Download datasheet (6Mb)Embed
PrevNext
Industrial Relays
®
TeSys
D IEC Style
Table 23.70: Time Delay Auxiliary Contact Blocks
Number and Type
of Contacts
1 N.C. and 1 N.O.
LADT
(Lockout Cover,
See page 7 of Catalog 8501CT0101.)
a
With extended scale from 0.1 to 0.6 s.
b
With switching time of 40 ms ± 15 ms between opening of the N.C. contact and closing of the N.O. contact.
Table 23.71: Mechanical Latch Blocks
Unlatching Control
Manual or electrical
c
Power should not be simultaneously applied or maintained to the mechanical latching block and the CAD relay. The duration of the control signal to the
mechanical latching block and the CAD relay should be Š 100 ms.
d
Repair part for the preceeding version (non-TeSys) of this product. Not for use on CAD devices.
LA6DK
e
Complete the catalog number by adding coil voltage code from Table 23.73. (for example, LA6DK10B)
Table 23.72: Coil Suppressor Modules
These modules clip onto the right hand side of the control relay and the electrical connection is instantly made. Adding an input
module is still possible.
RC Circuits (Resistor-Capacitor)
Effective protection for circuits highly sensitive to “high frequency” interference.
Voltage limited to 3 Uc maximum and oscillating frequency limited to 400 Hz maximum.
Slight increase in drop-out time (1.2 to 2 times the normal time).
For Mounting On:
CAD (Vac)
Varistors (Peak Limiting)
Protection provided by limiting the transient voltage value to 2 Uc maximum.
Maximum reduction of transient voltage peaks.
LAD4
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
CAD (Vac)
Bidirectional Peak Limiting Diode
Protection provided by limiting the transient voltage value to 2 Uc maximum.
Maximum reduction of transient voltage peaks.
CAD (Vac)
Table 23.73: Coil Voltage Codes
Voltage
Voltage Code
CAD (Vac Coil)
c
c1
c2
c3
CAD
b
Without cover or add-on blocks
c
With cover, without add-on blocks
23-16
Refer to Catalog 8501CT0101
Maximum Number
per Device
Time Delay Type
Termination Type
Front Mounting
Screw Clamp
On-Delay
1
Spring Terminal
Screw Clamp
Off-Delay
Spring Terminal
c
Maximum Number per Device
Front mounting
1
Operational Voltage
24 to 48 Vac
110 to 240 Vac
24 to 48 Vac
50 to 127 Vac
110 to 250 Vac
24 Vac
72 Vac
24
32/36
42/48
60/72
Vac/Vdc
Vac/Vdc
Vac/Vdc
Vac/Vdc
Vac/Vdc
B
C
E
EN
CAD (Vdc Coil) or (Low Consumption Vdc Coil)
0.49
1.77
45
12.5
(LAD-8)
in. (mm)
32
323
CAD
50
503
3.03 (77)
3.90 (99)
b
3.31 (84)
3.31 (84)
Without cover or add-on blocks
c
3.39 (86)
3.39 (86)
With cover, without add-on blocks
Discount
I12
Schedule
CAD
www.schneider-electric.us
Range
Catalog Number
0.1–3 s a
LADT0
0.1–30 s
LADT2
10–180 s
LADT4
1–30 s b
LADS2
0.1–3 s a
LADT03
0.1–30 s
LADT23
10–180 s
LADT43
1–30 s b
LADS23
0.1–3 s a
LADR0
0.1–30 s
LADR2
10–180 s
LADR4
0.1–3 s a
LADR03
0.1–30 s
LADR23
10–180 s
LADR43
Catalog Number
LA6DK10 ed
LAD6K10 e
Catalog Number
$ Price
LAD4RCE
26.20
LAD4RCU
26.20
LAD4VE
26.20
LAD4VG
26.20
LAD4VU
26.20
LAD4TB
26.20
LAD4TS
26.20
100
110/127
220/240
256/277
380/415
Vac/Vdc
Vac/Vdc
Vac/Vdc
Vac/Vdc
K
F
M
U
Q
1.77
c
45
c1
c2
c3
in. (mm)
32
323
50
503
3.03 (77)
3.90 (99)
3.66 (93)
3.66 (93)
3.74 (95)
3.74 (95)
© 2009 Schneider Electric
All Rights Reserved
$ Price
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
131.00
$ Price
77.00
77.00