E28F320J3A110 Intel, E28F320J3A110 Datasheet - Page 67

no-image

E28F320J3A110

Manufacturer Part Number
E28F320J3A110
Description
Manufacturer
Intel
Datasheet

Specifications of E28F320J3A110

Cell Type
NOR
Density
32Mb
Access Time (max)
110ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E28F320J3A110
Manufacturer:
INT
Quantity:
3 000
Part Number:
E28F320J3A110
Manufacturer:
INT
Quantity:
3 000
Part Number:
E28F320J3A110
Manufacturer:
AKM
Quantity:
20 790
Datasheet
Figure 26. Protection Register Programming Flowchart
FULL STATUS CHECK PROCEDURE
Write Protect. Register
Read Status Register
Read Status Register
Program Successful
Program Complete
Data (See Above)
Check if Desired
(Protection Reg.
Program Setup)
Address/Data
SR.3, SR.4 =
SR.1, SR.4 =
SR.1, SR.4 =
Write C0H
Full Status
SR.7 = 1?
Start
Yes
1, 1
0,1
1,1
No
Attempted Program to
Programming Error
Protection Register
Locked Register -
V
PEN
Aborted
Range Error
Protection Program operations can only be addressed within the protection
register address space. Addresses outside the defined space will return an
error.
Repeat for subsequent programming operations.
SR Full Status Check can be done after each program or after a sequence of
program operations.
Write FFH after the last program operation to reset device to read array mode.
SR.3 MUST be cleared, if set during a program attempt, before further
attempts are allowed by the Write State Machine.
SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command,
in cases of multiple protection register program operations before full status is
checked.
If an error is detected, clear the status register before attempting retry or other
error recovery.
Bus Operation
Bus Operation
Standby
Standby
Standby
Standby
Write
Write
Read
Protection Program
Protection Program
Command
Command
Setup
256-Mbit J3 (x8/x16)
Data = C0H
Data = Data to Program
Addr = Location to Program
Status Register Data Toggle
CE# or OE# to Update Status
Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
SR.1 SR.3 SR.4
0
0
1
1
0
0
Comments
Comments
1
1
1
V
Prot. Reg.
Prog. Error
Register
Locked:
Aborted
PEN
Low
67

Related parts for E28F320J3A110