GE28F320C3BD70 Intel, GE28F320C3BD70 Datasheet - Page 21

no-image

GE28F320C3BD70

Manufacturer Part Number
GE28F320C3BD70
Description
Manufacturer
Intel
Datasheet

Specifications of GE28F320C3BD70

Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
21b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
VFBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
2M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
C3 Discrete
5.0
5.1
Warning:
.
5.2
Table 6:
March 2008
290645-24
NOTICE: Specifications are subject to change without notice. Verify with your local Numonyx Sales office that you have the
latest datasheet before finalizing a design.
Extended Operating Temperature
Storage Temperature
Voltage On Any Pin (except V
V
V
Output Short Circuit Current
Notes:
1.
2.
3.
4.
T
V
V
V
V
V
V
A
PP
CC
CC1
CC2
CCQ1
CCQ2
CCQ3
PP1
Symbol
During Read
During Block Erase and Program
Temperature under Bias
Voltage (for Block Erase and Program) with Respect to GND
and V
Minimum DC voltage is –0.5 V on input/output pins. During transitions, this level may undershoot to –2.0 V
for periods <20 ns. Maximum DC voltage on input/output pins is V
overshoot to V
Maximum DC voltage on V
V
maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter blocks during program/
erase. V
Output shorted for no more than one second. No more than one output shorted at a time.
PP
CCQ
Program voltage is normally 1.65 V–3.6 V. Connection to a 11.4 V–12.6 V supply can be done for a
Supply Voltage with Respect to GND
Temperature and Voltage Operating Conditions
PP
Operating Temperature
V
I/O Supply Voltage
Supply Voltage
Maximum Ratings and Operating Conditions
Absolute Maximum Ratings
Stressing the device beyond the “Absolute Maximum Ratings” may cause permanent
damage. These ratings are stress ratings only. Operation beyond the “Operating
Conditions” is not recommended, and extended exposure beyond the “Operating
Conditions” may affect device reliability.
Operating Conditions
CC
may be connected to 12 V for a total of 80 hours maximum.
Supply Voltage
CC
+2.0 V for periods <20 ns.
CC
and V
Parameter
Parameter
PP
may overshoot to +14.0 V for periods <20 ns.
PP
) with Respect to GND
Notes
1, 2
1, 2
1
1
CC
+0.5 V which, during transitions, may
–40 °C to +85 °C
–40 °C to +85 °C
–40 °C to +85 °C
–65 °C to +125 °C
–0.5 V to +3.7 V
–0.5 V to +13.5 V
–0.2 V to +3.6 V
100 mA
1.65
1.65
Min
–40
2.7
3.0
2.7
1.8
Maximum Rating
Max
+85
3.6
3.6
3.6
2.5
2.5
3.6
Units
Volts
Volts
Volts
Datasheet
Notes
°C
1,2,3
1
4
21

Related parts for GE28F320C3BD70