GE28F320C3BD70 Intel, GE28F320C3BD70 Datasheet - Page 42

no-image

GE28F320C3BD70

Manufacturer Part Number
GE28F320C3BD70
Description
Manufacturer
Intel
Datasheet

Specifications of GE28F320C3BD70

Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
21b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
VFBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
2M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
Table 22: Device Identification Codes
10.1.3
10.1.4
Datasheet
42
Manufacturer ID
Device ID
Block Lock Status
Block Lock-Down Status
Protection Register Lock Status
Protection Register
Notes:
1.
2.
The address is constructed from a base address plus an offset. For example, to read the Block Lock Status for block
number 38 in a bottom boot device, set the address to 0x0F8000 plus the offset (0x02), i.e. 0x0F8002. Then examine
DQ0 of the data to determine if the block is locked.
See
Section 11.2, “Reading Block-Lock Status” on page 49
Item
CFI Query
The CFI query mode outputs Common Flash Interface (CFI) data after issuing the Read
Query Command (0x98). The CFI data structure contains information such as block
size, density, command set, and electrical specifications. Once in this mode, read cycles
from addresses shown in
information. To return to read-array mode, issue the Read Array command (0xFF).
Read Status Register
The Status Register indicates the status of device operations and the success/failure of
that operation. The Read Status Register (0x70) command causes subsequent reads to
output data from the Status Register until another command is issued. To return to
reading from the array, issue a Read Array (0xFF) command.
The Status Register bits are output on DQ[7:0]. The upper byte, DQ[15:8], outputs
0x00 when a Read Status Register command is issued.
The contents of the Status Register are latched on the falling edge of OE# or CE#
(whichever occurs last) which prevents possible bus errors that might occur if Status
Register contents change while being read. CE# or OE# must be toggled with each
subsequent status read, or the Status Register will not indicate completion of a
Program or Erase operation.
2
2
Base
Block
Block
Block
Block
Block
Block
Address
Appendix C, “Common Flash Interface,”
0x81 - 0x88
1
Offset
0x01
0x02
0x02
0x80
0x00
Register Data
DQ0 = 0b0
DQ0 = 0b1
DQ1 = 0b0
DQ1 = 0b1
Lock Data
0x88CC
0x88CD
0x0089
0x88C0
0x88C1
0x88C2
0x88C3
0x88C4
0x88C5
Data
for valid lock status.
8-Mbit Top Boot Device
8-Mbit Bottom Boot Device
16-Mbit Top Boot Device
16-Mbit Bottom Boot Device
32-Mbit Top Boot Device
32-Mbit Bottom Boot Device
64-Mbit Top Boot Device
64-Mbit Bottom Boot Device
Block is unlocked
Block is locked
Block is not locked-down
Block is locked down
Multiple reads required to read the
entire 128-bit Protection Register.
Description
retrieve the specified
C3 Discrete
March 2008
290645-24

Related parts for GE28F320C3BD70