TC58FVB321FT-10 Toshiba, TC58FVB321FT-10 Datasheet - Page 18

no-image

TC58FVB321FT-10

Manufacturer Part Number
TC58FVB321FT-10
Description
Manufacturer
Toshiba
Datasheet

Specifications of TC58FVB321FT-10

Cell Type
NOR
Density
32Mb
Access Time (max)
100ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP-I
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TC58FVB321FT-10
Manufacturer:
TOSHIBA
Quantity:
740
Part Number:
TC58FVB321FT-10
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TC58FVB321FT-10
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
DATA PROTECTION
The TC58FVT321/B321 includes a function which guards against malfunction or data corruption.
Protection against Program/Erase Caused by Low Supply Voltage
V
case, Auto operation is not executed again when V
need to be input to execute Auto operation again.
When V
Protection against Malfunction Caused by Glitches
shorter than 3 ns (Typ.) input on WE , CE or OE . However, if a glitch exceeding 3 ns (Typ.) occurs and the
glitch is input to the device malfunction may occur.
misinterpreted as part of a command sequence input and that the device will acknowledge it. Then, even if a
proper command is input, the device may not operate. To avoid this possibility, clear the Command Register
before command input. In an environment prone to system noise, Toshiba recommend input of a software or
hardware reset before command input.
Protection against Malfunction at Power-on
V
automatically Resets the Command Register and enters Read Mode.
LKO
IL
To prevent malfunction at power-on or power-down, the device will not accept commands while V
If V
To prevent malfunction during operation caused by noise from the system, the device will not accept pulses
The device uses standard JEDEC commands. It is conceivable that, in extreme cases, system noise may be
To prevent damage to data caused by sudden noise at power-on, when power is turned on with WE = CE =
the device does not latch the command on the first rising edge of WE or CE . Instead, the device
. In this state, command input is ignored.
DD
DD
drops below V
> V
LKO
, make up countermeasure to be input accurately command in system side please.
LKO
during an Auto Operation, the device will terminate Auto-Program execution. In this
DD
return to recommended V
TC58FVT321/B321FT/XB-70,-10
DD
voltage Therefore, command
2002-08-06 18/48
DD
is below