Specifications of AT28BV64B-25TI

Density
64Kb
Interface Type
Parallel
Organization
8Kx8
Access Time (max)
250ns
Write Protection
Yes
Data Retention
10Year
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-I
Operating Temp Range
-40C to 85C
Supply Current
15mA
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
28
Lead Free Status / Rohs Status
Not Compliant
4.4
4.5
4.6
4.6.1
4.6.2
4.7
4
DATA Polling
Toggle Bit
Data Protection
Device Identification
AT28BV64B
Hardware Protection
Software Data Protection
The AT28BV64B features DATA Polling to indicate the end of a write cycle. During a byte or
page write cycle an attempted read of the last byte written will result in the complement of the
written data to be presented on I/O7. Once the write cycle has been completed, true data is
valid on all outputs, and the next write cycle may begin. DATA Polling may begin at anytime
during the write cycle.
In addition to DATA Polling, the AT28BV64B provides another method for determining the end
of a write cycle. During the write operation, successive attempts to read data from the device
will result in I/O6 toggling between one and zero. Once the write has completed, I/O6 will stop
toggling and valid data will be read. Reading the toggle bit may begin at any time during the
write cycle.
If precautions are not taken, inadvertent writes may occur during transitions of the host system
power supply. Atmel
the memory against inadvertent writes.
Hardware features protect against inadvertent writes to the AT28BV64B in the following ways:
(a) V
time out 10 ms (typical) before allowing a write; (b) write inhibit – holding any one of OE low,
CE high or WE high inhibits write cycles; and (c) noise filter – pulses of less than 15 ns (typi-
cal) on the WE or CE inputs will not initiate a write cycle.
A software-controlled data protection feature has been implemented on the AT28BV64B. Soft-
ware data protection (SDP) helps prevent inadvertent writes from corrupting the data in the
device. SDP can prevent inadvertent writes during power-up and power-down as well as any
other potential periods of system instability.
The AT28BV64B can only be written using the software data protection feature. A series of
three write commands to specific addresses with specific data must be presented to the
device before writing in the byte or page mode. The same three write commands must begin
each write operation. All software write commands must obey the page mode write timing
specifications. The data in the 3-byte command sequence is not written to the device; the
addresses in the command sequence can be utilized just like any other location in the device.
Any attempt to write to the device without the 3-byte sequence will start the internal write tim-
ers. No data will be written to the device; however, for the duration of t
effectively be polling operations.
An extra 64 bytes of EEPROM memory are available to the user for device identification. By
raising A9 to 12V ± 0.5V and using address locations 7FC0H to 7FFFH, the additional bytes
may be written to or read from in the same manner as the regular memory array.
CC
power-on delay – once V
®
has incorporated both hardware and software features that will protect
CC
has reached 1.8V (typical) the device will automatically
WC
, read operations will
0299H–PEEPR–10/06