EQ2320-7R POWER ONE, EQ2320-7R Datasheet

no-image

EQ2320-7R

Manufacturer Part Number
EQ2320-7R
Description
DC/DC Power Supply Dual-OUT 12V 9.2A 120W 15-Pin
Manufacturer
POWER ONE
Type
Step Downr
Datasheet

Specifications of EQ2320-7R

Output Current
9.2 A
Output Voltage
12 V
Input Voltage
65 to 150 V
Number Of Outputs
2
Output Power
120 W
BCD20011-G Rev AD, 22-Dec-09
Description
These extremely compact DC-DC converters incorporate all
necessary input and output filtering, signaling, and protection
features, which are required in the majority of applications.
The converters provide important advantages such as flexible
output power through primary current limitation, high
efficiency, excellent reliability, very low ripple and RFI noise
levels, full input to output isolation, negligible inrush current,
overtemperature protection, and input over-/undervoltage
lockout. The converter inputs are protected against surges
and transients occurring on the source lines.
The
environment, such as railway applications. They have been
designed in accordance with the European railway standards
EN 50155 and EN 50121-3-2. All printed circuit boards are
coated with a protective lacquer.
The outputs are continuously open- and short-circuit proof. An
isolated output Power Good signal and LEDs at the front panel
indicate the status of the converter. Test sockets at the front
Table of Contents
Description .......................................................................... 1
Model Selection .................................................................. 2
Functional Description ........................................................ 5
Electrical Input Data ............................................................ 6
Electrical Output Data ......................................................... 8
Auxiliary Functions ............................................................ 16
converters
20
0.8"
4 TE
are
164
6.5"
®
particularly
111
4.4"
3 U
suitable
for
rugged
Page
Page 1 of 26
panel allow for a check of the main output voltage.
Full system flexibility and n+1 redundant operating mode are
possible due to virtually unrestricted series or parallel
connection capabilities of all outputs. In parallel connection of
several converters, automatic current sharing is provided by a
single-wire interconnection.
As a modular power supply or as part of a distributed power
supply system, the extremely low profile design significantly
reduces the necessary power supply volume without
sacrificing high reliability. A temperature sensor disables the
outputs, if the case temperature exceeds the limit. The outputs
are automatically re-enabled, when the temperature drops
below the limit.
The fully enclosed, black-coated aluminum case acts as a heat
sink and an RFI shield. The converters are designed for 19"
DIN-rack systems occupying 3U/4TE only, but can also be
chassis-mounted by means of four screws. It is possible to fit
an additional heat sink.
Electromagnetic Compatibility (EMC) ............................... 19
Immunity to Environmental Conditions ............................. 21
Mechanical Data ............................................................... 22
Safety and Installation Instructions ................................... 23
Description of Options ...................................................... 24
Accessories ....................................................................... 26
Features
• RoHS lead-free-solder and lead-solder-exempted
• Wide input voltage ranges up to 150 VDC
• 1 or 2 isolated outputs from 3.3 to 48 VDC
• Class I equipment
• Extremely high efficiency of up to 90%
• Flexible output power
• Excellent surge and transient protection
• Outputs open- and short-circuit proof
• Redundant operation, current sharing
• Extremely low inrush current, hot swappable
• Externally adjustable output voltage and inhibit
• Electric strength test 2.1 kVDC
• Very compact (<20 mm profile)
• Railway standards observed
• Telecoms-compatible input voltage range of 48Q
products are available
models according to ETS 300132-2 (38.4 – 75 VDC)
Safety according to IEC/EN 60950-1, UL/CSA 60950-1
66 – 132 Watt DC-DC Converter
Q Series Data Sheet
www.power-one.com
Page

Related parts for EQ2320-7R

EQ2320-7R Summary of contents

Page 1

U 164 20 6.5" 0.8" Description These extremely compact DC-DC converters incorporate all necessary input and output filtering, signaling, and protection features, which are required in the majority of applications. The converters provide important ...

Page 2

... VDC [%] 65 – 150 VDC [%] DQ1101-9 82* EQ1101-9 DQ1001-9R 85.5 EQ1001-9R 84.5 DQ2320-9R 88 EQ2320-9R DQ2540-9R 88 EQ2540-9R 87.5 DQ2660-9R 88 EQ2660-9R DQ2001-9R 85 EQ2001-9R DQ2320-9R 88 EQ2320-9R DQ2540-9R 88 EQ2540-9R 87.5 - B1, G DQ2660-9R 88 EQ2660-9R www.power-one.com Options 2 min - B1, G Options 2 min -7, B, B1 B1 B1, G ...

Page 3

Part Number Description Input voltage range 14.4 – ....................................................... B 21.6 – ....................................................... G 33.6 – ........................................................ C 38.4 – ..................................................... 48 43 – 108 V ......................................................... D ...

Page 4

Product Marking Type designation, applicable safety approval and recognition marks, CE mark, warnings, pin allocation, Power-One patents, and company logo. Identification of LEDs, test sockets, and potentiometer. Input voltage range and input current, nominal output voltages and currents, degree ...

Page 5

Functional Description The converters are designed as forward converters using primary and secondary control circuits in SMD technology. The switching frequency is approximately 200 kHz under nominal operating conditions. The built-in high-efficient input filter together with a small input ...

Page 6

Electrical Input Data General Conditions: – °C, unless T is specified – Sense lines connected directly at the connector, inhibit (28) connected to Vi – (32). – R input not connected; with option P, ...

Page 7

Input Fuse An incorporated fuse in series to the negative input line protects against severe defects. The fuse is not externally accessible. Reverse polarity at the input will cause the fuse to blow. Table 3: Fuse specifications Model Fuse ...

Page 8

Electrical Output Data General Conditions: – °C, unless T is specified – Sense lines connected directly at the connector, inhibit (28) connected to Vi – (32). – R input not connected; with option P, ...

Page 9

Table 5b: Output data for double-output models with both outputs in parallel configuration. General conditions as per table 5a Output Characteristics st V Setting voltage of 1 output o1 V Worstcase output voltage ow V Overvoltage limitation o P ...

Page 10

Table 6a: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration. General conditions as per table 5a. Output Characteristics Conditions 1 V Output setting voltage nom V ...

Page 11

Table 6b: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration. General conditions as per table 5a Output Characteristics Conditions 1 V Output setting voltage nom V ...

Page 12

Parallel and Series Connection Single- or double-output models with equal output voltage can be connected in parallel without any precaution by inter- connecting the T-pins for equal current sharing; see fig. 9a. Double-output models with their outputs connected in ...

Page 13

Redundant Configuration Fig. 10a shows a circuit with ORing diodes D output lines, forming a redundant configuration. For accurate output voltage regulation, the sense lines are connected after the ORing diodes. The T pins should be connected together to ...

Page 14

Note: If output 2 is not used, we recommend to connect it in parallel to Vo1. This results in improved efficiency and stability max ...

Page 15

... Fig. 16 Efficiency versus input voltage and output current (per output). Typical values of EQ2320 at V Hold-up Time The Q Series converters provide virtually no hold-up time. If hold-up time is required, use external output capacitors or decoupling diodes together with input capacitors of adequate size. Formula for additional external input capacitor: 2 • ...

Page 16

Auxiliary Functions Inhibit for Remote On/Off Note: If this function is not used, the inhibit pin 28 must be connected with pin 32 to enable the output(s). A non- connected pin 28 will be interpreted by the internal logic ...

Page 17

Programmable Output Voltage (R-Function) This feature is not available on models with 3.3 V output or with option P. Note: Models with 3.3 V output or with option P: The R-input must be left open-circuit. The converters offer a ...

Page 18

Output Good Signal (Out-OK) The isolated Out-OK output gives a status indication of the converter and the output voltage. It can be used for control functions such as data protection, central system monitoring part of a ...

Page 19

Electromagnetic Compatibility (EMC) A metal oxide VDR together with an input fuse and a symmetrical input filter form an effective protection against Electromagnetic Immunity Table 13: Immunity type tests Phenomenon Standard Level Supply related RIA 12 B surge EN ...

Page 20

... 0.2 Fig. 23c Conducted peak disturbances at the input: EQ2320-7R V102 nom o nom Radiated emissions have been tested according to IEC/EN 55011 (similar to EN 55022), as requested in EN 50121-3-2, table 6.1. The test is executed with horizontal and vertical polarization. The worse result is shown in fig. 24. ...

Page 21

Immunity to Environmental Conditions Table 15: Mechanical and climatic stress Test method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D section 507.2 Kb Salt mist, cyclic IEC/EN 60068-2-52 (sodium chloride NaCl solution) Fc Vibration IEC/EN 60068-2-6 (sinusoidal) MIL-STD-810D ...

Page 22

Mechanical Data The converters are designed to be inserted into a 19" rack according to IEC 60297-3. Dimensions are in mm. Fig. 25 Case Q 01, weight approx. 500 g Aluminium, fully enclosed, black finish, and self cooling Notes: ...

Page 23

Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 connector. Pin no. 26, the protective earth pin leading pin, ensuring that it ...

Page 24

Table 19: Isolation Characteristic Factory test ≥1 s Electric strength AC test voltage equivalent tests to factory test Insulation resistance Minimum creepage distances * Models with version V104 or higher. Older converters have only been tested with 0.3 kVDC. ...

Page 25

Table 21: Safety concept leading to an SELV output circuit Conditions Front end Nominal Minimum required grade supply of insolation pro- voltage vided by the AC-DC front end, including mains- supplied battery charger Mains Functional (i.e. there ...

Page 26

Accessories A great variety of electrical and mechanical accessories are available: • Various mating connectors including fast-on, screw, solder or press-fit terminals, code key system • Connector retention brackets CRB-Q [HZZ01217] • Cable connector housing (cable hood) KSG-H15/H15S4 [HZZ00141], ...

Related keywords