G6K2FDC24 Omron, G6K2FDC24 Datasheet

G6K2FDC24

Manufacturer Part Number
G6K2FDC24
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G6K2FDC24

Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
24V
Coil Current
4.6mA
Contact Form
2 Form C
Voltage Rating (vdc)
60V
Voltage Rating (vac)
125V
Dropout Volt (min)
2.4VDCV
Coil Resistance
5.22kohm
Pick-up Voltage (max)
19.2VDC
Maximum Power Rating
30W/37.5VA
Operate Time
3ms
Contact Current Rating
1A
Contact Material
Ag/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
5.2mm
Product Depth (mm)
7.8mm
Product Length (mm)
10mm
Operating Temp Range
-40C to 70C
Pin Count
8
Mounting Style
Surface Mount
Termination Style
Gull Wing
Lead Free Status / Rohs Status
Compliant
• Compact fourth generation design, offers excellent board
• Available in 2.54 and 3.2 mm coil-contact terminal spacing.
• “-Y” models meet 2.5 kV Bellcore surge requirements.
• Conforms to FCC Part 68.
• Terminal design based on Omron’s successful G6S relay.
• Available in PCB through-hole, SMT gullwing and SMT
• UL recognized / CSA certified.
• Available in single coil latching.
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5).
When ordering tape packing (surface mount versions), add “-TR” to the model number (e.g., G6K-2G-TR-DC5)
Specifications
■ Contact Data
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
Gullwing
Inside “L”
PCB through-hole
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note)
space savings.
“inside-L” terminals.
Low Signal Relay
G6K
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
Terminal
DPDT
Contact form
G6K-2F
G6K-2G
G6K-2P
Resistive load (cosφ=1)
0.3 A at 125 VAC
1 A at 30 VDC
Ag (Au clad)
1 A
125 VAC, 60 VDC
1 A
37.5 VA, 30W
10 μA at 10 mVDC
2.54 mm spacing
Non-latching
G6K-2F-Y
G6K-2G-Y
G6K-2P-Y
3.2 mm coil-contact
terminal spacing
Non-latching
Model
Low Signal Relay
G6KU-2F-Y
G6KU-2G-Y
G6KU-2P-Y
3.2 mm coil-contact
Single coil latching
terminal spacing
G6K
RC
67

Related parts for G6K2FDC24

G6K2FDC24 Summary of contents

Page 1

... Available in 2.54 and 3.2 mm coil-contact terminal spacing. • “-Y” models meet 2.5 kV Bellcore surge requirements. • Conforms to FCC Part 68. • Terminal design based on Omron’s successful G6S relay. • Available in PCB through-hole, SMT gullwing and SMT “inside-L” terminals. ...

Page 2

Coil Data G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P) G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y) Rated voltage Rated current Coil resistance (VDC) (mA) (Ω) 3 33.0 91 4.5 23.2 194 5 ...

Page 3

Characteristic data Maximum Switching Capacity AC resistive load DC resistive load Rated operating voltage (V) Note: The maximum coil voltage refers to the maxi- Electrical Service Life 30 VDC resistive load Ambient temperature: 23°C Switching frequency: 1,800 operations/hour 125 ...

Page 4

Contact Reliability Test (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y NO Sample: G6K-2G contact Number of Relays Test conditions resistive load at contact 10 mVDC with an operation rate Switching frequency: 7,200 operations/h 3 ...

Page 5

Must Operate and Must Release Time Distribution (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y Sample: G6K-2G Must operate Number of Relays: 50 Must release time Time (ms) Note: The tests were conducted at an ambient temperature of 23°C. ■ Approvals UL ...

Page 6

G6K-2F-Y Note: Each value has a tolerance of ±0.3 mm. G6K-2G-Y Note: Each value has a tolerance of ±0.3 mm. G6K-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of ±0.3 mm. ...

Page 7

Packaging Information Tube packing Standard nomenclature Tape packing When ordering, add “TR” before the rated coil voltage (e.g., G6K-2G-TR-DC5). Note not part of the relay model number and will not be marked on the relay. (SMT versions, ...

Page 8

... Time (s) • The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern. • In order to perform correct soldering recommended that the correct soldering conditions be maintained as shown below on the left side. Correct Soldering ...

Page 9

Must not cause thermal changes in or deterioration of the insulating material. • Must not cause damage to other control devices. • Must not cause any harmful effect on people. • Must not cause fire. Therefore, be sure to ...

Page 10

MEMO G6K 76 Low Signal Relay ...

Page 11

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 12

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords