Specifications of ZBZ1604

Features
Red, Metal
Rohs Compliant
Yes
For Use With
40mm Emergency Stop And Mushroom Head Pushbuttons
04/2005
Pilot Lights – UL Types 4, 13/NEMA Type 4 & 13
For use in hazardous locations – See page 150. Legend Plates Not Included
Push-To-Test Ground Detector Pilot Light
(Contact Block Included — But NOT Legend Plate or Color Cap)
Basic Operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 155
Boots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 154
Lamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 148
Legend Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152-153
Light Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 148
Outline Dimensions
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 149-150
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 158
Ring Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 158
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 148
Used in pairs to indicate a grounded condition in a control circuit fed from a grounded center-
tapped transformer. The Type KT50 is commonly used in press control circuits, and fulfills the
requirements of the ground detector called for in ANSI B11.1 (1971), Par. E3.6.5. Consult
local Square D Sales Office for proper application.
Add the voltage assembly code as chosen from voltage assembly code table on page 134.
EXAMPLE: KT
Add the color code as chosen from the color cap table. EXAMPLE: KP1
fresnel cap = KP1L31
The color cap must be the same color as the LED voltage chosen (i.e., green LED use a
green color cap) or use clear cap.
On neon voltages use clear color caps only.
On remote test pilot lights use only full voltage or resistor voltage assembly codes. Do not
choose LED, neon or transformer codes. For AC use only.
Color
Amber
Green
Yellow
White
Clear
Blue
Red
Voltage and Frequency
110-120 V, 50-60 Hz
Description
R31 with a 60VAC red LED voltage=KT37LRR31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 159-160
Standard Pilot Light
Color Cap Shown)
Plastic Fresnel
Push To Test Pilot
(Glass Color Cap
Remote Test Pilot
(Glass Color Cap
(NEMA Type 4X)
(Plastic fresnel
Pilot Light For
Safe Circuits
Intrinsically
W31
C31
G31
R31
A31
L31
Y31
Shown)
Shown)
Light
Light
Intrinsically safe equipment must not release electrical or thermal energy capa-
ble of igniting certain explosive or combustible hazardous atmospheres, for
which the equipment has been tested.
These pilot lights are intrinsically safe when used with a suitable approved bar-
rier or barrier relay (Class 8501 Type TO or NY2). These pilot lights are Factory
Mutual (FM approved). Consult your local Square D Sales Office for further de-
tails.
These pilot lights are fully encapsulated – there are no replaceable parts – ex-
cept for the SK40 ring nut. Use KN100 series plastic legend plates as shown on
pages 152 and 153.
For Other Voltages See
110-120 V, 50-60 Hz
220-240 V, 50-60 Hz
110-120 V, 50-60 Hz
220-240 V, 50-60 Hz
Plastic Domed
For Other Voltages
For Other Voltages
24-28 Vac Only
See Table
Voltage Range
24-28 Vac-dc
24-28 Vac-dc
120 Vac Only
See Table
Operating
W9
G9
A9
L9
C9
R9
Y9
Voltage
Table
20-30 V
AC/DC
Push Buttons and Operator Interface - Type K and SK, 30 mm
➀➄
KT50
Type
Nominal Current
Glass
G6
W6
A6
C6
R6
Y6
L6
with a blue
25 mA
Full Voltage, Neon or Resistor
Full Voltage, Neon or Resistor
Transformer, Flashing or LED
Transformer, Flashing or LED
Full Voltage or Resistor
Full Voltage
Transformer
Transformer
Transformer
Transformer
Full Voltage
Full Voltage
Resistor
Style
Typical Wiring Diagrams
I max. = 165 mA
V max. = 32 V
© 1999-2005 Schneider Electric All Rights Reserved
L1
L1
1
TEST
BUTTON
Voltage Assembly Codes
Heavy Duty Pilot Lights - Type K
STOP
Fresnel Color
KTR38R31
KTR35R31
KTR
With Red
KP35R31
KT35R31
KP
KP
KT
KT
KP1R31
KP7R31
KT1R31
KT7R31
KP44R
Push-To-Test Pilot Light
STOP
Remote Test Pilot Light
LSI
Cap
M3
See Page 134
2
R31
R31
R31
R31
R31
START
M
Fresnel Color
(TEST) C
With Green
KTR38G31
KTR35G31
KTR
(TEST) C
KP35G31
KP
KP
KT35G31
KT
KT
(TEST) C
KP1G31
KP7G31
KT1G31
KT7G31
KP44G
Cap
START
3
G31
G31
G31
G31
Test
G31
L2
C
L1
L1
(SIG)
L1
(SIG)
L1
(SIG)
M
R
L2
M
L2
L2
With Other
Color Cap
KTR38
KTR35
KTR
KP35
KT35
CR
KP
KP
KT
KT
M2
KP1
KP7
KT1
KT7
KP44Y
(Yellow
M1
Color
Cap)
O.L.
➀➁
➀➁
➀➁
➀➁
➀➁
L2
L2
Color Cap
Without
KTR38
KTR35
KTR
KP
KP
KP35
KT35
KT
KT
KP1
KP7
KT1
KT7
135

Related parts for ZBZ1604