ATV12H075M2 Crouzet USA, ATV12H075M2 Datasheet

11R1089

ATV12H075M2

Manufacturer Part Number
ATV12H075M2
Description
11R1089
Manufacturer
Crouzet USA
Datasheets

Specifications of ATV12H075M2

No. Of Phases
Single
Power Rating
0.75kW
Output Voltage Max
230V
Frequency Range
0.5 To 400Hz
Output Current
4.2A
Supply Voltage Max
230V
Rohs Compliant
Yes
Altivar
12
®
variable speed drives
For 3-phase motors from 0.18 to 4 kW
Catalog
2010

Related parts for ATV12H075M2

ATV12H075M2 Summary of contents

Page 1

Altivar ® variable speed drives For 3-phase motors from 0. Catalog 2010 12 ...

Page 2

2 ...

Page 3

Contents Altivar 12 ® variable speed drives Overview ...

Page 4

The Altivar 12 variable speed drive gives you greater reliability 6 ® and simplicity of operation to run all your applications. • The smallest drive with integrated EMC for compact 7 machines • Ever more ...

Page 5

The Altivar 12 is well-suited for use in applications involving simple industrial machines or certain consumer machines. Its compact size, high performance and discreet appearance make it particularly attrac- tive for use in ...

Page 6

Altivar 12: High-performance plus easy integration and configuration . . . Easy to integrate – the Altivar extremely efficient drive. Its design and rugged components make it both reliable and durable compromise on quality • ...

Page 7

The Altivar 12 variable speed drive is immediately operational. It’s configured using ® its notched wheel or from the SoMove software workshop. The file that is generated can be downloaded ...

Page 8

Selection guide Type of machine Power range for (kW) line supply Single-phase 100 to 120 V (kW) Single-phase 200 to 240 V (kW) Three-phase 200 to 230 V (kW) 4 Three-phase 200 to ...

Page 9

Pumps and fans (industrial) 0.37 to 800 – 0.37 to 5.5 – 0. 0.75 to 630 – 2.2 to 7.5 – 2.2 to 800 0.1 to 500 Hz for the entire range 0.1 to 599 ...

Page 10

Introduction 1 2 ATV12 drive controlling an access barrier ATV12 drive controlling a mixer ATV12 drive controlling a pumping station Specifications: References: page 10 page 14 8 Altivar 12 ® variable speed ...

Page 11

... Introduction (continued) Drive with heatsink Drive on base plate ATV12H075M2 ATV12P075M2 ATV12H075M2 with door on front panel open Multi-Loader configuration tool Remote terminal with cover Remote terminal with cover closed open: RUN, FWD/REV and STOP buttons accessible Specifications: References: page 10 page 14 Altivar 12 ® ...

Page 12

Specifications Environmental specifications Conformity to standards 1 EMC immunity 2 Conducted EMC ATV12ppppF1 emissions for ATV12H018M3 3 drives ATV12p037M3 to pU22M3 ATV12ppppM2 4 5 Radiated EMC ATV12pppppp emissions for drives e marking Product certifications 6 Degree of protection Vibration resistance ...

Page 13

Specifications (continued) Drive specifications Output frequency range Configurable switching frequency Speed range Transient overtorque Braking torque Maximum transient current Motor control profiles Electrical power specifications Power supply Voltage Frequency Isc (short-circuit current) Drive supply and output voltages ATV12ppppF1 ATV12ppppM2 ATV12ppppM3 ...

Page 14

Specifications (continued) Electrical specifications (control) Available internal supplies 1 Analog input AI1 2 Analog output AO1 3 Relay outputs R1A, R1B, R1C 4 LI logic inputs LI1 to LI4 5 Positive logic (Source) Negative logic (Sink) 6 Logic output LO+, ...

Page 15

Specifications (continued) Communication port specifications Protocol Structure Connector Physical interface Transmission mode Transmission speed Number of subscribers Polarization Address Services Profile Messaging Communication monitoring Diagnostics Via the Human/Machine interface or remote display terminal Torque specifications (typical curves) T/Tn 2 1,7 ...

Page 16

... A W (4) 2.1 18 ATV12H018F1 (5) 3.6 29 ATV12H037F1 6.3 48 ATV12H075F1 (4) (6) 2.1 18 ATV12H018M2 (5) (7) 3.6 27 ATV12H037M2 (7) 5.3 34 ATV12H055M2 (7) 6.3 44 ATV12H075M2 (7) 11.2 72 ATV12HU15M2 ( ATV12HU22M2 (8) (4) 2.1 16 ATV12H018M3 (5) 3.6 24 ATV12H037M3 6.3 41 ATV12H075M3 ATV12HU15M3 11 ATV12HU22M3 18.3 94 ATV12HU30M3 25 128 ATV12HU40M3 (4) 2.1 ...

Page 17

References (continued) Accessories Description Mounting plates for mounting wide DIN rail VW3A9804 EMC conformity kits These provide a connection compliant with EMC standards (see page 23) The kit consists of: The EMC plate Clamps Fixing accessories VW3A9523 ...

Page 18

... The SoMove Mobile software requires a basic mobile phone; please consult our website “www.schneider-electric.us”. (2) Please consult our website “www.schneider-electric.us”. (3) Minimum value of the resistor to be used: 75 ohms. (4) Minimum value of the resistor to be used: 51 ohms. 10 ATV12H075M2 with EMC kit VW3A9523 mounted on EMC filter VW3A4416 Introduction: Specifications: ...

Page 19

... Motor chokes, Modbus serial link, ® documentation, replacement parts Nominal current For drives A 4 ATV12H018F1, H037F1 ATV12H018M2 to H055M2 ATV12H018M3, H037M3 ATV12P037F1 ATV12P037M2, P055M2 ATV12P037M3 10 ATV12H075F1 ATV12H075M2, HU15M2 ATV12H075M3, HU15M3 ATV12P075M2 ATV12P075M3, PU15M3 16 ATV12HU22M2 ATV12HU22M3, HU30M3 ATV12PU22M3, PU30M3 30 ATV12HU40M3 ATV12PU40M3 Item no. Length m 1 – ...

Page 20

Dimensions Drives with heatsinks (1) ATV12H018F1, H037F1, ATV12H018M2 to H075M2, ATV12H018M3 to H075M3 1 2xØ ATV12 H018F1 (1), H018M2 (1), H018M3 (1) 142 H037F1, H037M2, H037M3 H055M2, H075M2, H075M3 (1) Due to the poor heat dissipation, ...

Page 21

Dimensions , (continued) mounting recommendations Drives on a base plate ATV12P037F1, ATV12P037M2 to P075M2, ATV12P037M3 to P075M3 2xØ5 60 102 ATV12PU15M3, PU22M3 2xØ5 98 105 ATV12PU30M3, PU40M3 4xØ5 126 100,2 = 140 Recommendations for mounting ...

Page 22

Dimensions (continued) Accessories Mounting plates for mounting on an AM1 VW3A9804 2 37,9 77,5 Options Remote display terminal VW3A1006 7,7 50 Braking resistors VW3A7701, 702 (2 flying leads 0.5 m long 4xØ6x12 70 95 VW3 ...

Page 23

Mounting recommendations Mounting recommendations Operating temperature according to the mounting type Mounting type Type A mounting Type B mounting (2) Type C mounting ( (1) Value given for a switching frequency of ...

Page 24

Connections Recommended connections Typical connection for ATV12ppppF1, ATV12ppppM2 1 Single-phase power supply KM1 Note: Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as ...

Page 25

Connections , (continued) installation recommendations Recommended connections (continued) Braking unit VW3A7005 used with braking resistors VW3A7701, 702, 723, 724 ATV12pppppp PA Braking Braking unit resistor VW3A7 005 VW3A77pp PB Additional EMC input filters VW3A4416 to 419 Single-phase power supply VW3A4416, ...

Page 26

Combinations for customer assembly Q1: or C60N2P 5 KM1: TeSys LC1ppp (if control circuit) A1: 6 ATV12ppppF1, ATV12ppppM2 M1: 7 200..240 V three-phase M1 asynchronous motor 3 Motor starter with single-phase power supply ...

Page 27

Combinations for customer assembly (continued) Q1: or Q1: C60N4P GV2pppp KM1: TeSys LC1pppp (if control circuit) A1: ATV12ppppM3 M1: M1 200..240 V three-phase 3 asynchronous motor Motor starter with three-phase power supply Introduction: Specifications: page 8 page 10 Altivar 12 ...

Page 28

Functions Introduction: Specifications: page 8 page 10 26 Altivar 12 ® variable speed drives Summary of functions Factory-set drive configuration Introduction Human/Machine Interface (HMI) Description Application functions Operating speed range ...

Page 29

... ATV12H075M2 with door on front panel closed with protective cover 5: STOP/RESET and RUN buttons not accessible ATV12H075M2 with door on front panel closed without protective cover 5: STOP/RESET and RUN buttons accessible ATV12H075M2 with door on front panel open REF Reference MODE MODE Parameter Monitoring ...

Page 30

Functions (continued Setting preset speeds with the SoMove setup software Introduction: Specifications: page 8 page 10 28 Altivar 12 ® variable speed drives Application functions Operating speed range Determines the two frequency limits which define the speed range permitted by the machine under actual operating conditions within the specified torque limits. ...

Page 31

Functions (continued) PID ramp PID + reference PIC PID reversal X±1 PID feedback RPG FBS PID regulator RIG Speed Multiplier ramp Auto HSP LSP Man. Manual setpoint Auto/man. FBS: PID feedback multiplication coefficient HSP: High speed PIC: Change of direction of PID regulator correction ...

Page 32

Functions (continued (Hz) f (Hz) HSP HSP HSP: High speed (k1: fixed rounding coefficient) t2: Ramp time set 4 S ramps f (Hz) f (Hz) HSP HSP ...

Page 33

Functions (continued) Introduction: Specifications: page 8 page 10 Altivar 12 ® variable speed drives Limiting low speed operating time The motor is stopped automatically after a period of operation at low speed (LSP). This time can be set between 0.1 ...

Page 34

Functions (continued Setting the “DC injection” function with the SoMove setup software 4 5 Energy saving with the Pump/Fan profile ( (Hz) 8 ± Frequency jump in relation ...

Page 35

Functions (continued) Setting the motor thermal protection with the SoMove setup software Introduction: Specifications: page 8 page 10 Altivar 12 ® variable speed drives Fault relay, unlocking The fault relay is energized when the drive is powered up and is ...

Page 36

Functions (continued Introduction: Specifications: page 8 page 10 34 Altivar 12 ® variable speed drives Underload detection This function stops the motor when it is underloaded. The function is active ...

Page 37

Functions (continued) 1 Single variable mode 2 Single variable mode with auxiliary pump Variable pump frequency (Hz) 3 HSP 1 FOn 3 FOF 2 Installation flow rate Single variable mode with auxiliary pump: hysteresis Introduction: Specifications: page 8 page 10 Altivar 12 ...

Page 38

Functions (continued LSP: Low speed SLE: Sleep threshold offset UPP: Wake-up threshold tLS: Sleep threshold operating time LPI: PID feedback supervision threshold HSP: High speed FPI: Fallback speed APO: Maximum speed detection hysteresis ...

Page 39

Functions (continued) HSP: High speed SFS: Quick start threshold ACC: Acceleration ramp time Introduction: Specifications: page 8 page 10 Altivar 12 ® variable speed drives Quick start The quick start function aims to overcome the problems associated with the high ...

Page 40

Schneider Electric USA, Inc. 8001 Knightdale Blvd. Knightdale, NC 27545 Tel: 919-266-3671 19 Waterman Avenue Toronto, Ontario M4B 1Y2 Tel: 416-752-8020 ART. 960297 http://www.schneider-electric.us/ The information and dimensions in this catalog are provided for the convenience of our customers. While this information is ...