VI-J0Y-EY Vicor Corporation, VI-J0Y-EY Datasheet

no-image

VI-J0Y-EY

Manufacturer Part Number
VI-J0Y-EY
Description
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VI-J0Y-EY
Manufacturer:
VICOR
Quantity:
78
Part Number:
VI-J0Y-EY
Manufacturer:
VICOR
Quantity:
334
Part Number:
VI-J0Y-EY
Quantity:
34
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Features
Product Highlights
The Input Attenuator Module (VI-IAM) is a
component-level, DC input front end filter
designed to occupy minimum board space
while providing maximum protection for
today’s sophisticated electrical systems.
The VI-IAM, in combination with Vicor 24,
48 and 300Vdc input modules, provides a
highly efficient, high density power system
with outputs from 1 to 95Vdc and power
expandable from 25 to 800W. Your system
will benefit from the small size, efficiency
and inherent reliability of Vicor’s compo-
nent-level converters, while meeting the
toughest demands of Telecommunications
and Industrial power applications.
This combination provides compliance
with the transient requirements of
Bellcore, British Telecom and IEC stan-
dards, and meets the EMI/RFI specifica-
tions of Bellcore, British Telecom and FCC
Part 15, Subpart B and EN55022.
Compatible Products
• VI-200, VE-200, VI-J00, VE-J00
• Mega Modules
EMI/RFI specifications:
RoHS Compliant (VE-IAM)
Inputs: 24, 48 and 300 Vdc
High surge withstand:
cULus, CTÜVus
97% efficiency
Input reverse polarity protection
Logic disable
Expansion output for arrays
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
CE Marked
(Inputs: 1, W, 3, N and 6)
(Inputs: 1, W, 3, N and 6)
Bellcore
British Telecom BTR 2511
IEC-60801-5
Bellcore TR-TSY-000513
British Telecom BTR 2511
FCC Level “A”
EN55022 Level “B”
Factorized Power
Set your site on VICOR at www.vicorpower.com
VI-IAM Specifications
(typical at T
PARAMETER
Input Range/Power Limit
VI-A11-CU / VE-A11-CU
VI-AWW-CU / VE-AWW-CU
VI-A33-CQ / VE-A33-CQ
VI-ANN-CQ / VE-A33-CQ
VI-A66-CQ / VE-A66-CQ
Isolation
Size
Weight
EMI/ RFI (conducted
emissions)
Transient Protection
Reverse Polarity Protection
Product Grade Specifications
PARAMETER
Storage Temp.
Operating Temp.
Note: For alternative product grades, change the “C” in the part number to “E”, “I” or “M”
Data Sheet
VI-IAM ™, VE-IAM
Input Attenuator Modules
(Baseplate)
BP
= 25°C, nominal line, 75% load, unless otherwise specified)
–20°C to +105°C
–10°C to +100°C
VI-IAM Input Attenuator Modules
E
200Vdc
21Vdc
18Vdc
42Vdc
36Vdc
MIN
2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7)
3.0 Ounces (85 Grams)
Meets Bellcore TR-TSY-000513, Issue 2, Rev. 1
(24 and 48V Input);
British Telecom BTR 2511, Issue 2
(24 and 48V Input);
FCC Part 15, Class A, EN55022 Class B
Meets Bellcore TA-TSY-001003, Issue 1, 9/89
British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only)
No damage to unit
1,500 VRMS
300Vdc
24Vdc
24Vdc
48Vdc
48Vdc
–40°C to +105°C
–25°C to +100°C
TYP
C
400Vdc
32Vdc
36Vdc
60Vdc
76Vdc
MAX
PRODUCT GRADE
–55°C to +105°C
–40°C to +100°C
POWER
200W
200W
400W
400W
400W
(RoHS Compliant)
I
Rev.1.1
Delivered power is
of DC-DC converters
Input/Output to Base
from any combination
REMARKS
–65°C to +105°C
–55°C to +100°C
M
Page 1 of 2

Related parts for VI-J0Y-EY

VI-J0Y-EY Summary of contents

Page 1

... Input); British Telecom BTR 2511, Issue 2 (24 and 48V Input); FCC Part 15, Class A, EN55022 Class B Transient Protection Meets Bellcore TA-TSY-001003, Issue 1, 9/89 British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only) Reverse Polarity Protection No damage to unit Product Grade Specifications PARAMETER E Storage Temp. – ...

Page 2

... VI-IAM (53, 0.15 (3,8) 0.12 (3,0) Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com 24V Inputs Wide Range R.E. 100V 160V I.S.W. S.D. Full Load 100V 36V 60V 18V 42V 1 ...

Related keywords