FARM1C11 Vicor Corporation, FARM1C11 Datasheet

no-image

FARM1C11

Manufacturer Part Number
FARM1C11
Description
500/750W; inputV:90-132V; outputV:250-370V; 30A; FARM: filter/autoranging rectifier module
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FARM1C11
Manufacturer:
VICOR
Quantity:
387
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
The FARM (Filter/Autoranging Rectifier
Module) is an AC front-end module which
provides EMI filtering, autoranging line
rectification and inrush current limiting. The
FARM is available in either 500/750 W or
750/1000 W models in a mini sized package
measuring only 2.28" x 2.2" x 0.5".
The FARM interfaces directly with
worldwide AC mains and may be used with
Vicor 300 V input DC-DC converters to
realize an autoranging, high density, low
profile switching power supply. The FARM
includes a microcontroller that continuously
monitors the AC line to control bridge /
doubler operation. The user need only
provide external capacitance to satisfy
system hold-up requirements.
Vicor 2nd Generation packaging technology
offers flexible mounting options for various
manufacturing processes. The FARM may be
installed as a conventional leaded device
for onboard applications, inboard for low
profile, height restricted applications,
socketed or surface mounted with optional
ModuMate interconnect products.
RoHS compliant (with F or G pin style)
EMI filtering
Choice of 500 W or 750 W modules
96% efficiency
Autoranging 115/230 Vac input
Microprocessor controlled
Inrush current limiting
Mini sized package
Power fail signal
Module enable
Set your site on VICOR at vicorpower.com
FARM
*Pin styles S, N, F & G are compatible with the ModuMate interconnect system for socketing and surface mounting.
Parameter
L to N voltage
+Out to –Out voltage
B OK to –Out voltage
EN to –Out voltage
Mounting torque
Operating temperature
Storage temperature
Pin soldering temperature
Output current
Baseplate temperature
FARM
Parameter
Baseplate to sink
Baseplate to ambient
Product
flat, greased surface
with thermal pad (P/N 20264)
Free convection
1000 LFM
57,9 x 55,9 x 12,7 mm
Shown actual size:
2.28 x 2.2 x 0.5 in
1 = 500/750 W
2 = 750/1000 W
Type
FARM, Filter/Autoranging Rectifier Module
1
Grade
Product Grade Temperatures (°C)
E =
C =
T =
H =
–10 to +100
– 20 to +100
– 40 to +100
– 40 to +100
Operating
4 – 6(0.45 – 0.68)
– 55 to 125
–40 to 100
500 (260)
750 (390)
Rating
C
264
280
400
100
3.5
16
16
– 20 to +125
– 40 to +125
– 40 to +125
– 55 to +125
Storage
Min
in-lbs (N-m)
Typ
0.16
0.14
°F (°C)
°F (°C)
8.0
1.9
1 = Short Pin
2 = Long Pin
S = Short ModuMate
N = Long ModuMate
F = Short RoHS
G = Long RoHS
Unit
Vac
Vac
Vdc
Vdc
Vdc
°C
°C
°C
A
Pin Style*
1
Rev. 6.0
Max
Notes
Continuous
100 ms
6 each, 4-40 screw
H-Grade
H-Grade
<5 sec; wave solder
<7 sec; hand solder
Unit
1 = Slotted
2 = Threaded
3 = Thru hole
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Baseplate
Page 1 of 11
1

Related parts for FARM1C11

FARM1C11 Summary of contents

Page 1

RoHS compliant (with pin style) • EMI filtering • Choice of 500 W or 750 W modules • 96% efficiency • Autoranging 115/230 Vac input • Microprocessor controlled • Inrush current limiting • Mini sized package • ...

Page 2

Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to ...

Page 3

SAFETY SPECIFICATIONS (FARM1xxx, FARM2xxx) Parameter Min Isolation voltage (in to out) Dielectric withstand 2,121 (I/O to baseplate) Leakage current AGENCY APPROVALS Safety Standards FARM1 xxx UL60950, EN60950, CSA 60950 FARM2 xxx UL60950, EN60950, CSA 60950 GENERAL SPECIFICATIONS Parameter MTBF Baseplate ...

Page 4

Vdc output Strap Engaged Enable B OK Figure 1 — Start up at 120 Vac input I ac input @ Enable B OK Figure 3 — Power down, from 120 Vac Vdc output Figure 5 — Output ...

Page 5

The Filtered, Autoranging Rectifier Module (FARM) provides an effective solution for the AC frontend of a power supply built with Vicor DC-DC converters. This high-performance power system building block satisfies a broad spectrum of requirements and agency standards. In addition ...

Page 6

The FARM maintains the DC output bus voltage between 250 and 370 Vdc over the entire input voltage range, which is compatible with Vicor 300 V input converters. The FARM automatically switches to the proper bridge or doubler mode depending ...

Page 7

Not used with VI-260/VI-J60 Vdc BOK EMI GND 150 k ST FARM N/C EN Micro- controller – L Figure 10 — Enable (EN) function + N +5 Vdc 15 Vdc BOK EMI GND Secondary ST referenced N/C ...

Page 8

The power fail warning time (Δt) is defined as the interval between B OK and converter shut down (EN) as illustrated in Fig. 13. The Bus-OK and Enable thresholds are 205 V and 190 V, respectively. A simplified relationship between ...

Page 9

Ripple (V p-p) Figure 13 — Hold-up time 250 500 Operating Power (W) Figure 14 — Power fail warning time vs. operating power and total bus capacitance, series combination of C1, ...

Page 10

Converter Pins No. Function Label 1 Neutral N 2 EMI GND 3 NC 0.23 4 Line L (REF) 5,8 5 –Out – 0.300 ±0.015 6 Enable EN 7,62 ±0,38 7 Strap ST 8 BUS OK BOK 0.300 ±0.015 7,62 ±0,38 ...

Page 11

Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...

Related keywords