MI-J21-MY Vicor Corporation, MI-J21-MY Datasheet

no-image

MI-J21-MY

Manufacturer Part Number
MI-J21-MY
Description
Vicor Corporation [Military DC-DC Converters 10 to 50W]
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MI-J21-MY
Manufacturer:
VICOR
Quantity:
228
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Features
• Inputs:
• Single output: 2 – 48 Vdc
• Up to 23 W/in
• MIL-STD-810 environments
• Up to 90% efficiency
• Remote sense
• Current limit
• ZCS power architecture
• Low noise FM control
• Size: 2.28" x 2.4" x 0.5"
Product Highlights
The MI-J00 family of DC-DC converters is
designed for applications utilizing distributed
power architectures. Based on Vicor’s VI-200 /
VI-J00 family of zero-current switching,
component-level DC-DC converters, the MI-J00
family offers exceptional performance in terms of
power density, efficiency, noise, ease of use, and
reliability.
The MI-J00 family meets all steady-state,
transient and under/overvoltage requirements of
MIL-STD-704D/E/F for both 28 Vdc input
(MI-J2X) and 270 Vdc input (MI-J6X), and the
worst case envelope of MIL-STD-1399A for
155 Vdc input (MI-J5X).
The output voltage can be externally trimmed or
programmed from 50% to 110% of nominal
output. Current limiting, remote sense, and an
inhibit pin all combine to offer a high degree of
protection, versatility, and reliability for power
systems.
Fully encapsulated in Vicor’s industry standard
package, the MI-J00 family meets MIL-STD-810
environmental testing requirements for humidity,
fungus, salt-fog, explosive atmosphere,
acceleration, vibration, and shock.
Packaging Options
Standard: Slotted baseplate
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - JXX - XX - S
FinMod: Finned heat sink, option suffix:
Examples:
MI - JXX - XX -F1, 0.25" fins, longitudinal
MI - JXX - XX -F2, 0.50" fins, longitudinal
MI - JXX - XX -F3, 0.25" fins, transverse
MI - JXX - XX -F4, 0.50" fins, transverse
28 Vdc per MIL-STD-704D/E/F
155 Vdc per MIL-STD-1399A
270 Vdc per MIL-STD-704D/E/F
(57,9 x 61,0 x 12,7 mm)
- F1, -F2, -F3 and - F4
3
Set your site on VICOR at www.vicorpower.com
MI-J
Data Sheet
MI-J00
DC-DC Converters
10 to 50 Watts
Converter Selection Chart
[a]
[b]
[c]
Semi-custom modules available, consult factory.
Nominal
2 = 28 V
5 = 155 V
6 = 270 V
7 = 165 V
Transient voltage for 1 second.
16 V operation at 75% load.
These units rated at 75% load from 125 – 150 Vin: MI-J6Z-xY, MI-J6Y-xY, MI-J60-xY
W = 5.5 V
M = 10 V
R = 7.5 V
Y = 3.3 V
X = 5.2 V
V = 5.8 V
Z = 2.0 V
0 = 5.0 V
T = 6.5 V
Input Voltage
Output Voltage
MI-200 DC-DC Converters 10 to 50 Watts
100 – 210 V
125 – 400 V
100 – 310 V
18 – 50 V
Range
P = 13.8 V
N = 18.5 V
K = 40 V
L = 28 V
1 = 12 V
2 = 15 V
3 = 24 V
J = 36 V
4 = 48 V
[b]
[c]
Transient
230 V
475 V
60 V
n/a
M = –55 to +100
I = –40 to +100
[a]
Product Grade Temperatures (°C)
Output Power/Current Vout
Operating
A = 10 W
Z = 25 W
Y = 50 W
≥ 5 V
Notes
28 Vdc input per MIL-STD 704D/E/F
155 Vdc input per MIL-STD-1399A
270 Vdc input per MIL-STD-704D/E/F
Rev. 1.0
M = –65 to +125
I = –55 to +125
A = —
Z = 5 A
Y = 10 A
Storage
< 5 V
Page 1 of 6

Related parts for MI-J21-MY

MI-J21-MY Summary of contents

Page 1

... V 230 V [ 270 V 125 – 400 V 475 165 V 100 – 310 V [a] Transient voltage for 1 second. [ operation at 75% load. [c] These units rated at 75% load from 125 – 150 Vin: MI-J6Z-xY, MI-J6Y-xY, MI-J60-xY Output Voltage ...

Page 2

... CONVERTER SPECIFICATIONS (typical 25°C, nominal line and 75% load, unless otherwise specified) BP INPUT SPECIFICATIONS Parameter Min Inrush charge Input reflected ripple current – pp Input ripple rejection No load power dissipation OUTPUT CHARACTERISTICS Parameter Min Setpoint accuracy Load/line regulation Output temperature drift Long term drift Output ripple – ...

Page 3

... Typ Max %/hours Typ Max 3,732 1,000 hours 672 1,000 hours 526 1,000 hours Typ Max 3.0 Ounces (85) (Grams) MI-200 DC-DC Converters Watts Units Test Conditions V Baseplate earthed RMS V RMS V RMS pF Units Test Conditions With thermal pads Units Test Conditions feet ...

Page 4

... Shock MIL-STD-202F, Method 213B saw tooth shock MIL-STD-202F, Method 207A, 3 impacts / axis feet Acceleration MIL-STD-810D, Method 513.3, Procedure II Operational test for 1 minute along 3 mutually perpendicular axes Humidity MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity Solder Test MIL-STD-202, Method 208, 8 hr. aging Fungus MIL-STD-810C, Method 508 ...

Page 5

... Dia (7) places .15 Solder plate (3,8) over copper alloy Product ID this surface 1.90 (48,3) .22 (5,6) Min. +.030 (0,76) .50 -.000 (0) (12,7) .01 MI-200 DC-DC Converters Watts RoHS 0.080 Dia (2) places Matte tin over copper alloy Pin # Function + Gate In 3 Gate Out 4 -In +Out ...

Page 6

... Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. ...

Related keywords