Page 1
... Generation converter. This converter is manufactured in a state-of-the-art automated manufacturing facility on a short-cycle-time robotic line having a capacity of one module every ten seconds. In-line process controls are designed to achieve low defect rates and consistent quality. A comprehensive CIM system controls the dispatching, assembly ...
Page 2
... Power sharing accuracy Programming range 10 Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com Typ Max Unit 24 36 ...
Page 3
... Isolation voltage (out to base) 500 Isolation resistance (in to out) Weight Temperature limiting 100 Agency approvals available UL, CSA, TÜV, BABT, CE, VDE Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com Typ Max Unit 5.75 6.00 Vdc 2.1 3 ...
Page 4
... The module may be disabled by pulling PC below 2.3V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 1. Primary Auxiliary Supply At 5.7V, PC can source up to 1.5mA. In the example shown in Figure 3, PC powers a module enabled LED ...
Page 5
... D Vnom - Vout Figure 7—Output voltage trim down circuit. Trim Down 1. This converter is not a constant power device – it has a constant current limit. Hence, available output power is reduced by the same percentage that output voltage is trimmed down. Do not exceed maximum rated output current. 2. The trim down resistor must be connected to the –Sense pin. ...
Page 6
... At the discretion of the power system designer, a subset of all modules within an array may be configured as slaves by shorting SC to –S. • OR’ing diodes may be inserted in series with the +Out pins of each module to provide module output fault tolerance. 24Vin/48Vout/400W DC-DC Converter +In PC 0.001µ ...
Page 7
... DENOTES 1.000* 25,40 TOL = 0.195 1.400* 35,56 4,95 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com 0.50 0.02 12,7 0,5 2.20 55,9 4-40 UNC-2B 0.12* 0.20** Thru (4X)*** 3,1 5,08 1.74 (Style 2 and 3 only) ...
Page 8
... PART NUMBERS & OPTIONS Part Number VI-982437 Short Solder VI-982438 Long Solder VI-982439 Short ModuMate VI-982440 Long ModuMate VI-982441 Short Solder VI-982442 Long Solder VI-982443 Short ModuMate VI-982444 Long ModuMate VI-982445 Short Solder VI-982446 Long Solder VI-982447 Short ModuMate VI-982448 Long ModuMate ...
Page 9
... Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. ...