FMP12-R85 TDK Corporation, FMP12-R85 Datasheet

no-image

FMP12-R85

Manufacturer Part Number
FMP12-R85
Description
Manufacturer
TDK Corporation
Datasheet
AC Input
Single Output, General-Purpose
F Series FMP/FMP-B(3 to 10W)
The F series FMP/FMP-B has realized a thickness of 20mm max.
by the TDK original technology such as increased switching fre-
quencies and a thin-type transformer or filter. It has an equivalent
level of the FCC class B in the noise terminal voltage in spite of the
compact size. An onboard-type FMP-B is included in the lineup.
FEATURES
• AC.100V input thin-type single output power supply.
• Compact plastic package type.
• Low price.
• Low noise (FCC class B compliant).
• It is a product conforming to RoHS directive.
PPART NUMBERS AND RATINGS
FMP
Output voltage
(V)
5
12
24
FMP-B
Output voltage
(V)
5
12
24
• The above products are only produced upon receipt of order. Please check a delivery date.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
• All specifications are subject to change without notice.
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
3W Type
Current(A)
0.06 to 0.6
0.02 to 0.25 FMP12-R25
0.01 to 0.13 FMP24-R13
3W Type
Current(A)
0.06 to 0.6
0.02 to 0.25 FMP12-R25B
0.01 to 0.13 FMP24-R13B
Part No.
FMP05-R60
Part No.
FMP05-R60B
10W Type
Current(A)
0.2 to 2
0.08 to 0.85 FMP12-R85
0.04 to 0.45 FMP24-R45
10W Type
Current(A)
0.2 to 2
0.08 to 0.85 FMP12-R85B
0.04 to 0.45 FMP24-R45B
Part No.
FMP05-2R0
Part No.
FMP05-2R0B
Conformity to RoHS Directive
003-01 / 20051205 / ea122_fmp.fm
(1/12)

Related parts for FMP12-R85

FMP12-R85 Summary of contents

Page 1

... PBB and PBDE, have not been used, except for exempted applications. • All specifications are subject to change without notice. 10W Type Current(A) Part No. 0 FMP05-2R0 0.08 to 0.85 FMP12-R85 0.04 to 0.45 FMP24-R45 10W Type Current(A) Part No. 0 FMP05-2R0B 0.08 to 0.85 FMP12-R85B 0.04 to 0.45 FMP24-R45B (1/12) Conformity to RoHS Directive 003-01 / 20051205 / ea122_fmp.fm ...

Page 2

... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. ∗ 4 Output may fail to come on when operated in series. • All specifications are subject to change without notice. ∗ 4 FMP12-R25 12V • 0.25A 3 70typ. 12 10.8 to 13.2 0.25 ...

Page 3

FMP3W Type SHAPES AND DIMENSIONS ® [Detail drawing of terminal block(187 Faston tab)] t=0.5 ø1.5 2-C1 3.2 (6.35) • Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m) • Faston ® ...

Page 4

... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. ∗ 4 Output may fail to come on when operated in series. • All specifications are subject to change without notice. ∗ 4 FMP12-R85 12V • 0.85A 10.2 78typ. 12 10.8 to 13.2 0.85 ...

Page 5

FMP10W Type SHAPES AND DIMENSIONS ® [Detail drawing of terminal block(187 Faston tab)] t=0.5 ø1.5 2-C1 3.2 (6.35) • Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m) ® • Faston ...

Page 6

... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. ∗ 4 Output may fail to come on when operated in series. • All specifications are subject to change without notice. ∗ 4 FMP12-R25B 12V • 0.25A 3 70typ. 12 10.8 to 13.2 0.25 ...

Page 7

FMP-B3W Type SHAPES AND DIMENSIONS 55 t=0.5 4±0.5 • Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m) • When mounted on PCB, must solder after insert M3. TERMINAL DESIGNATIONS AND ...

Page 8

... Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage. ∗ 4 Output may fail to come on when operated in series. • All specifications are subject to change without notice. ∗ 4 FMP12-R85B 12V • 0.85A 10.2 78typ. 12 10.8 to 13.2 0.85 ...

Page 9

FMP-B10W Type SHAPES AND DIMENSIONS 55 t=0.5 4±0.5 • Do not insert M3 installation screws more than 6mm into the power supply. (Recommend torque 0.48N • m) • When mounted on PCB, must solder after insert M3. TERMINAL DESIGNATIONS AND ...

Page 10

Characteristics, Functions, and Applications COMMON SPECIFICATIONS Temperature and humidity Operating(°C) Temperature range Storage(°C) Operating(%)RH Humidity range Storage(%)RH Vibration and shock 5 to 10Hz Vibration 10 to 55Hz Acceleration Shock Pulse duration Withstand voltage and insulation resistance Input terminal to ground ...

Page 11

Characteristics, Functions, and Applications START UP TIME(25°C, RATED INPUT AND OUTPUT) 3W TYPE FMP05-R60 (4/4/4)ms Output voltage AC input H:10ms/DIV 10W TYPE FMP05-2R0 (6.5/6/5)ms Output voltage AC input H:10ms/DIV HOLD UP TIME(25°C, RATED INPUT AND OUTPUT) 3W TYPE FMP05-R60 Output ...

Page 12

Characteristics, Functions, and Applications INPUT/OUTPUT TERMINAL For input/output terminals, 187-type Faston terminals are commercially available from various terminal manu- facturers. Two manufacturing companies among them will be intro- duced below. These terminals can be soldered, though it is undesirable to ...

Related keywords