BT8370KPF

Manufacturer Part NumberBT8370KPF
DescriptionFully integrated T1/E1 framer and line interface
ManufacturerConexant Systems, Inc.
BT8370KPF datasheet
 


Specifications of BT8370KPF

CaseQFP  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
Page 161
162
Page 162
163
Page 163
164
Page 164
165
Page 165
166
Page 166
167
Page 167
168
Page 168
169
Page 169
170
Page 170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
Page 170/323

Download datasheet (3Mb)Embed
PrevNext
3.8 Receiver Registers
Enable RLOF Integration—When set, the receive loss of frame status [RLOF; addr 047] is
RLOF_INTEG
integrated for 2.0 to 2.5 seconds during T1 framer modes (not applicable to E1 modes). RLOF
interrupt status [ISR7; addr 004] is also integrated. However, receive framer status in ALM3
[addr 049], loss of frame count [FRED[3:0]; addr 05A] and RLOF counter overflow [ISR4;
addr 007] are unaffected. RLOF_INTEG does not meet the requirements of TR62411. To meet
the requirements of TR62411 “Conditions Causing The Initiation of Carrier Failure Alarms,”
the receive loss of frame condition reported by FRED (addr 049) must be integrated before
initiating Yellow Alarm Transmission. This can be accomplished in software by integrating
FRED during an RLOF Interrupt (ISR7; addr 004), with RLOF_INTEG bit cleared.
Send AIS on RPCMO Output Pin—Replaces RPCMO data with a continuous series of all 1s.
RPCM_AIS
RPCM_AIS is useful in CSU or digital section applications, where the local interface must be
able to forward an AIS to the opposing interface.
046— Alarm/Error/Counter Latch Configuration (LATCH)
7
6
5
Stop Error Count during RLOF/RLOS/RAIS—When enabled, error count registers [addr
STOP_CNT
050–057] are suspended at their present values during one of the following conditions: receive
loss of frame (RLOF), loss of signal (RLOS), or all 1s (RAIS) alarm condition. STOP_CNT
does not affect the counting of test pattern errors [BERR; addr 058, 059] or alarm events
[AERR; addr 05A]. The occurrence of a red or AIS CGA inhibits further processing of all
other performance parameters (i.e., BER, errored seconds, SLIPS). However, a CGA caused
by a Yellow Alarm does not inhibit further alarm or performance monitoring.
Enable ONESEC Latching of Counters—Determines the interval for which error counts
LATCH_CNT
remain held in all count registers [addr 050–057]. LATCH_CNT must be active in T1 mode
whenever automatic 1-second performance report messaging [AUTO_PRM; addr 0AA] is
enabled. LATCH_CNT is active during E1 mode; the processor cannot use the RLOF counter
overflow [addr 007] as a 128 ms MFAS timeout.
When the LATCH_CNT is inactive, the processor read of the LSB register reports the
current LSB error count, it latches the current MSB error count to the MSB register, and then it
clears LSB. Subsequently, reading the MSB register reports current latched MSB error count
and then clears MSB.
3-52
Fully Integrated T1/E1 Framer and Line Interface
0 = normal RLOF status
1 = integrated RLOF [addr 047] status
0 = normal RPCMO data
1 = RPCMO replaced with all ones
4
3
STOP_CNT
LATCH_CNT
0 = Continue error count during alarms
1 = Stop error count during alarms
LATCH_CNT
Count Latched
0
Never
1
ONESEC interval
Conexant
Bt8370/8375/8376
2
1
0
LATCH_ERR
LATCH_ALM
Count Hold Time
Until read clear
ONESEC interval
N8370DSE