BT8370KPF

Manufacturer Part NumberBT8370KPF
DescriptionFully integrated T1/E1 framer and line interface
ManufacturerConexant Systems, Inc.
BT8370KPF datasheet
 


Specifications of BT8370KPF

CaseQFP  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
Page 81
82
Page 82
83
Page 83
84
Page 84
85
Page 85
86
Page 86
87
Page 87
88
Page 88
89
Page 89
90
Page 90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
Page 90/323

Download datasheet (3Mb)Embed
PrevNext
2.0 Circuit Description
2.8 Transmitter
Automatic generation of Yellow Alarm(YB2) is controlled by AUTO_YEL,
RLOF, and RLOF_INTEG. If AUTO_YEL is set, Yellow Alarm is generated
during a Receive Loss of Frame alignment (RLOF = 1). Optionally, RLOF
integration can be enabled by setting RLOF_INTEG. In this case, both RLOF
indication and Yellow Alarm/RAI generation are delayed for approximately 2.5
seconds if a continuous out of frame condition exists. Yellow Alarm/RAI
generation continues for at least 1 second after RLOF clears. Refer to
Table 2-13. Multiframe Yellow Alarm Generation
Line Rate
T1
E1
In T1 ESF framing mode, Multiframe Yellow Alarm or RAI is transmitted
using BOP Codeword Transmitter [TBOP; addr 0A1] and does not depend on
INS_MYEL. Transmitting Yellow Alarm/RAI toward the line can be done upon
receiving Receive Loss of Frame. T1 multiframe Yellow Alarm must be generated
by configuring TDL1 to transmit an all-0s BOP codeword. Optionally, RLOF
integration can be enabled by setting RLOF_INTEG. In this case, both RLOF
indication and Yellow Alarm/RAI generation are delayed for approximately
2.5 seconds if a continuous out of frame condition exists. Yellow Alarm/RAI
generation continues for at least 1 second after RLOF clears. RLOF_INTEG does
not meet the requirements of TR62411. To meet the requirements of TR62411,
“Conditions Causing the Initiation of Carrier Failure Alarms,” the Receive Loss
of Frame condition reported by FRED (addr 049) must be integrated before
initiating Yellow Alarm Transmission. This can be accomplished in software by
integrating FRED during an RLOF Interrupt (ISR7; addr 004), with
RLOF_INTEG bit cleared.
In E1 CAS framing modes, Multiframe Yellow Alarm is inserted into the
transmit stream to alert far-end equipment that local received multiframe
alignment is not recovered. E1 Multiframe Yellow Alarm is transmitted by setting
the Y bit in time slot 16, frame 0.
Transmission of Multiframe Yellow Alarm is controlled by the register bits
listed in
Table 2-14. Multiframe Yellow Alarm Register Bits
INS_MYEL
TMYEL
AUTO_MYEL
SRED
2-62
Fully Integrated T1/E1 Framer and Line Interface
Multiframe Yellow Alarm Action
Facilitates Yellow Alarm Action (requires
programming TDL1)
Set Y bit TS16 in frame 0 to 1
Table
2-14:
Bit Name
Register
[TFRM; addr 072]
[ TALM; addr 075]
[ TALM; addr 075]
[ALM3; addr 049]
Conexant
Bt8370/8375/8376
Table
2-13.
Mode
YF
Y16
N8370DSE