MC68HC705J1A

Manufacturer Part NumberMC68HC705J1A
ManufacturerMotorola
MC68HC705J1A datasheet
 


Specifications of MC68HC705J1A

CaseDIP-20L  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
Page 91
92
Page 92
93
Page 93
94
Page 94
95
Page 95
96
Page 96
97
Page 97
98
Page 98
99
Page 99
100
Page 100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
Page 98/162

Download datasheet (2Mb)Embed
PrevNext
Computer Operating Properly (COP) Module
7.3 Operation
Operation of the COP is described in this subsection.
7.3.1 COP Watchdog Timeout
Four counter stages at the end of the timer make up the COP watchdog.
The COP resets the MCU if the timeout period occurs before the COP
watchdog timer is cleared by application software and the IRQ/V
voltage is between V
a new timeout period and prevents COP reset. A COP watchdog timeout
indicates that the software is not executing instructions in the correct
sequence.
NOTE:
The internal clock drives the COP watchdog. Therefore, the COP
watchdog cannot generate a reset for errors that cause the internal clock
to stop.
The COP watchdog depends on a power supply voltage at or above a
minimum specification and is not guaranteed to protect against
brownout.
7.3.2 COP Watchdog Timeout Period
The COP watchdog timer function is implemented by dividing the output
of the real-time interrupt circuit (RTI) by eight. The RTI select bits in the
timer status and control register control RTI output, and the selected
output drives the COP watchdog. See timer status and control register
in
Section 9. Multifunction Timer
NOTE:
The minimum COP timeout period is seven times the RTI period. The
COP is cleared asynchronously with the value in the RTI divider; hence,
the COP timeout period will vary between 7x and 8x the RTI period.
7.3.3 Clearing the COP Watchdog
To clear the COP watchdog and prevent a COP reset, write a logic 0 to
bit 0 (COPC) of the COP register at location $07F0 (see
Technical Data
98
and V
. Periodically clearing the counter starts
SS
DD
Computer Operating Properly (COP) Module
PP
Module.
Figure
7-1).
MC68HC705J1A — Rev. 4.0
MOTOROLA
pin