The higher C

Download datasheet (124Kb)Embed
PrevNext
30A
15A
0A
t=0ns
t
Figure 11. ESD Test Waveform for IEC1000-4-2
discharge current rather than the discharge
voltage. Variables with an air discharge such as
approach speed of the object carrying the ESD
potential to the system and humidity will tend to
change the discharge current. For example, the
rise time of the discharge current varies with the
approach speed.
The Contact Discharge Method applies the ESD
current directly to the EUT. This method was
devised to reduce the unpredictability of the
ESD arc. The discharge current rise time is
constant since the energy is directly transferred
without the air-gap arc. In situations such as
hand held systems, the ESD charge can be directly
SP202E
HUMAN BODY
Family
MODEL
Driver Outputs
±15kV
Receiver Inputs
±15kV
Table 2. Transceiver ESD Tolerance Levels
Date: 7/19/04
discharged to the equipment from a person already
holding the equipment. The current is transferred
on to the keypad or the serial port of the equipment
directly and then travels through the PCB and
finally to the IC.
The circuit models in Figures 9 and 10 represent
the typical ESD testing circuit used for all three
methods. The C
power supply when the first switch (SW1) is on.
Now that the capacitor is charged, the second
switch (SW2) is on while SW1 switches off. The
voltage stored in the capacitor is then applied
through R
, the current limiting resistor, onto the
t=30ns
S
device under test (DUT). In ESD tests, the SW2
switch is pulsed so that the device under test
receives a duration of voltage.
For the Human Body Model, the current limiting
resistor (R
) and the source capacitor (C
S
1.5kΩ an 100pF, respectively. For IEC-1000-4-
2, the current limiting resistor (R
capacitor (C
S

The higher C

IEC1000-4-2 model are more stringent than the
Human Body Model. The larger storage capacitor
injects a higher voltage to the test point when
SW2 is switched on. The lower current limiting
resistor increases the current charge onto the test
point.
IEC1000-4-2
Air Discharge
Direct Contact
±15kV
±15kV
SP202E Series High Performance RS232 Transceivers
10
is initially charged with the DC
S
) are
S
) and the source
S
) are 330Ω an 150pF, respectively.
value and lower R
value in the
S
S
Level
4
±8kV
±8kV
4
© Copyright 2004 Sipex Corporation