K4J55323QG-BC14 Samsung, K4J55323QG-BC14 Datasheet

no-image

K4J55323QG-BC14

Manufacturer Part Number
K4J55323QG-BC14
Description
Manufacturer
Samsung
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
K4J55323QG-BC14
Manufacturer:
SAMSUNG
Quantity:
25 520
Part Number:
K4J55323QG-BC14
Quantity:
5 510
Part Number:
K4J55323QG-BC14
Manufacturer:
AVAGO
Quantity:
4 300
Part Number:
K4J55323QG-BC14
Manufacturer:
SAMSUNG
Quantity:
983
Part Number:
K4J55323QG-BC14
Manufacturer:
SAMSUNG
Quantity:
16 506
Part Number:
K4J55323QG-BC14
Manufacturer:
SAMSUNG
Quantity:
6 472
K4J55323QG
Notice
INFORMATION IN THIS DOCUMENT IS PROVIDED IN RELATION TO SAMSUNG PRODUCTS,
AND IS SUBJECT TO CHANGE WITHOUT NOTICE.
NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS GRANTING ANY LICENSE,
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,
TO ANY INTELLECTUAL PROPERTY RIGHTS IN SAMSUNG PRODUCTS OR TECHNOLOGY. ALL
INFORMATION IN THIS DOCUMENT IS PROVIDED
ON AS "AS IS" BASIS WITHOUT GUARANTEE OR WARRANTY OF ANY KIND.
1. For updates or additional information about Samsung products, contact your nearest Samsung office.
2. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar
* Samsung Electronics reserves the right to change products or specification without notice.
applications where Product failure could result in loss of life or personal or physical harm, or any military or
defense application, or any governmental procurement to which special terms or provisions may apply.
256Mbit GDDR3 SDRAM
Revision 1.3
June 2006
- 1 /53 -
256M GDDR3 SDRAM
Rev. 1.3 June 2006

Related parts for K4J55323QG-BC14

K4J55323QG-BC14 Summary of contents

Page 1

... K4J55323QG 256Mbit GDDR3 SDRAM Notice INFORMATION IN THIS DOCUMENT IS PROVIDED IN RELATION TO SAMSUNG PRODUCTS, AND IS SUBJECT TO CHANGE WITHOUT NOTICE. NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS GRANTING ANY LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IN SAMSUNG PRODUCTS OR TECHNOLOGY. ALL INFORMATION IN THIS DOCUMENT IS PROVIDED ON AS " ...

Page 2

... K4J55323QG Revision History Revision Month Year 0.0 February 2005 0.1 March 2005 0.2 March 2005 0.3 April 2005 0.4 May 2005 1.0 June 2005 1.1 November 2005 1.2 March 2006 1.3 June 2006 - Target Spec - Changed EMRS table for Driver Impedance control. - Typo corrected. - Added clock frequency change sequence on page 18 and IBIS spec on page 19~21 - Reduced Cin min ...

Page 3

... Programmable Write latency : and 7 (clock) • Single ended READ strobe (RDQS) per byte • Single ended WRITE strobe (WDQS) per byte 2.0 ORDERING INFORMATION Part Number K4J55323QG-BC12 K4J55323QG-BC14 K4J55323QG-BC16 K4J55323QG-BC20 K4J55323QC-AC** is leaded package part number 3.0 GENERAL DESCRIPTION FOR 2M x 32Bit x 4 Bank GDDR3 SDRAM ...

Page 4

... K4J55323QG 4.0 PIN CONFIGURATION Normal Package (Top View VDDQ VDD B VSSQ DQ0 C VDDQ DQ2 D VSSQ WDQS0 E VDDQ DQ4 F VDD DQ6 G VSS VSSQ H VREF A1 J VSSA RFU1 K VDDA A10 L VSS VSSQ M VDD DQ24 N VDDQ DQ26 P VSSQ WDQS3 R VDDQ DQ28 T VSSQ DQ30 V VDDQ ...

Page 5

... K4J55323QG 5.0 INPUT/OUTPUT FUNCTIONAL DESCRIPTION Symbol Type Clock: CK and CK are differential clock inputs. CMD, ADD inputs are sampled on the crossing of the positive CK, CK Input edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). CK, CK should be maintained stable, except self-refresh mode Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers ...

Page 6

... K4J55323QG 6.0 BLOCK DIAGRAM (2Mbit x 32I Bank) Bank Select iCK ADDR LCKE LRAS LCBR iCK CKE * iCK : internal clock WDQS Input Buffer Input Buffer Data Input Register Serial to parallel Column Decoder Latency & Burst Length ...

Page 7

... K4J55323QG 7.0 FUNCTIONAL DESCRIPTION 7.1 Simplified State Diagram Power Applied Power On Precharge PREALL MRS EMRS Write A PREALL = Precharge All Banks MRS = Mode Register Set EMRS = Extended Mode Register Set REFS = Enter Self Refresh REFSX = Exit Self Refresh REFA = Auto Refresh REFS REFSX MRS ...

Page 8

... K4J55323QG 7.2 INITIALIZATION GDDR3 SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. 1. Apply power and keep CKE/RESET at low state ( All other inputs may be undefined) - Apply VDD and VDDQ simultaneously - Apply VDDQ before Vref. ( Inputs are not recognized as valid until after V 2 ...

Page 9

... K4J55323QG 7.3 MODE REGISTER SET(MRS) The mode register stores the data for controlling the various operating modes of GDDR3 SDRAM. It programs CAS latency, address- ing mode, test mode and various vendor specific options to make GDDR3 SDRAM useful for variety of different applications. The default value of the mode register is not defined, therefore the mode register must be written after EMRS setting for the proper opera- tion ...

Page 10

... K4J55323QG PROGRAMMABLE IMPEDANCE OUTPUT BUFFER AND ACTIVE TERMINATOR The GDDR3 SDRAM is equipped with programmable impedance output buffers and Active Terminators. This allows a user to match the driver impedance to the system. To adjust the impedance, an external precision resistor(RQ) is connected between the ZQ pin and Vss. The value of the resistor must be six times of the desired output impedance. ...

Page 11

... K4J55323QG CAS LATENCY (READ LATENCY) The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the first bit of output data. The latency can be set to 4~15 clocks READ command is registered at clock edge n, and the latency is m clocks, the data will be available nominally coincident with clock edge n+m ...

Page 12

... K4J55323QG WRITE LATENCY The Write latency (WL) is the delay, in clock cycles, between the registration of a WRITE command and the availability of the first bit of input data. The latency can be set from clocks depending in the operating frequency and desired current draw. When the write latencies are set clocks, the input receivers never turn off when the WRITE command is registered ...

Page 13

... K4J55323QG TEST MODE The normal operating mode is selected by issuing a MODE REGISTER SET command with bits A7 set to zero, and bits A0-A6 and A8- A11 set to the desired values. Test mode is entered by issuing a MODE REGISTER SET command with bit A7 set to one, and bits A0- A6 and A8-A11 set to the desired values. Test mode functions are specific to each Dram Manufacturer and its exact functions are hidden from the user ...

Page 14

... K4J55323QG 7.4 EXTENDED MODE REGISTER SET(EMRS) The extended mode register stores the data output driver strength and on-die termination options. The extended mode register is writ- ten by asserting low on CS, RAS, CAS, WE and high on BA0(The GDDR3 SDRAM should be in all bank precharge with CKE already high prior to writing into the extended mode register) ...

Page 15

... K4J55323QG DLL ENABLE/DISABLE The DLL must be enabled for normal operation. DLL enable is required during power-up initialization and upon returning to normal oper- ation after disabling the DLL for debugging or evaluation. (When the device exits self refresh mode, the DLL is enabled automatically.) Any time the DLL is enabled, 20K clock cycles must occur before an any command can be issued. ...

Page 16

... K4J55323QG 7.5 MANUFACTURERS VENDOR CODE AND REVISION IDENTIFICATION The Manufacturers Vendor Code selected by issuing a EXTENDED MODE REGISTER SET command with bits A10 set to one, and bits A0-A9 and A11 set to the desired values. When the V function is enabled the GDDR3 SDRAM will provide its manufacturers ...

Page 17

... K4J55323QG 7.6 Clock frequency change sequence during the device operation Both existing tCK and desired tCK are in DLL-On mode - Change frequency from existing frequency to desired frequency - Issue Precharge All Banks command - Issue MRS command to reset the DLL while other fields are valid and required 20K tCK to lock the DLL - Issue Precharge All Banks command ...

Page 18

... K4J55323QG 7.7 BOUNDARY SCAN FUNCTION GENERAL INFORMATION The 256Mb GDDR3 incorporates a modified boundary scan test mode as an optional feature. This mode doesn’t operate in accor- dance with IEEE Standard 1149.1 - 1990. To save the current GDDR3 ball-out, this mode will scan parallel data input and output and the scanned data through WDQS0 pin controlled by an add-on pin, SEN which is located 136 ball package ...

Page 19

... K4J55323QG BOUNDARY SCAN EXIT ORDER BIT# BALL BIT# BALL 1 D-3 13 E-10 2 C-2 14 F-10 3 C-3 15 E-11 4 B-2 16 G-10 5 B-3 17 F-11 6 A-4 18 G-9 7 B-10 19 H-9 8 B-11 20 H-10 9 C-10 21 H-11 10 C-11 22 J-11 11 D-10 23 J-10 12 D-11 24 L-9 *Note : 1. When the device is in scan mode, the mirror function will be disabled and none of the pins are remapped. 2. Since the other input of the MUX for DM0 tied to GND, the device will output the continuous zeros after scanning a bit #67, if the chip stays in scan shift mode. ...

Page 20

... K4J55323QG SCAN DC ELECTRICAL CHARACTERISTICS AND OPERATING CONDITIONS PARAMETER/CONDITON Input High (Logic 1) Voltage Input Low (Logic 0) Voltage *Note : 1. The parameter applies only when SEN is asserted. 2. All voltages referenced to GND. SCK SEN LOW SSH SOE Pins under Test SCK SEN SSH SOE SOUT ...

Page 21

... K4J55323QG SCAN AC ELECTRICAL CHARACTERISTICS PARAMETER/CONDITON Clock Clock cycle time Scan Command Time Scan enable setup time Scan enable hold time Scan command setup time for SSH, SOE# and SOUT Scan command hold time for SSH, SOE# and SOUT Scan Capture Time ...

Page 22

... K4J55323QG 7.8 Mirror Function The GDDR3 SDRAM provides a mirror function (MF) ball to change the physical location of the control lines and all address lines which helps to route devices back to back. The MF ball will affect RAS, CAS, WE, CS and CKE on balls H3, F4, H9, F9 and H4 respectively and A0, A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, BA0 and BA1 on balls K4, H2, K3, M4, K9, H11, K10, L9, K11, M9, K2, L4, G4 and G9 respectively and only detects a DC input ...

Page 23

... K4J55323QG 7.9 OPERATIONS 7.9.1 BANK/ROW ACTIVATION Before any READ or WRITE commands can be issued to a banks within the GDDR3 SDRAM, a row in that bank must be “opened.” This is accomplished via the ACTIVE command, which selects both the bank and the row to be activated. After a row is opened with an ACTIVE command, a READ or WRITE command may be issued to that row, subject to the t specification ...

Page 24

... K4J55323QG 7.9.2 READs READ bursts are initiated with a READ command, as below figure. The starting column and bank addresses are provided with the READ command and auto precharge is either enabled or disabled for that burst access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst after t the generic READ commands used in the following illustrations, auto precharge is dis- abled ...

Page 25

... K4J55323QG Data Output Timing ( DQSQ CK# CK 1.6 RDQS DQ(Last data valid) DQ(First data no longer valid) 5 All DQs and RDQS, collectively Data Output Timing ( DQSQ CK# CK 1.6 RDQS 5 All DQs and RDQS, collectively 1.6 RDQS 5 All DQs and RDQS, collectively Note : 1. t represents the skew between the 8 DQ lines and the respective RDQS pin. ...

Page 26

... K4J55323QG READ Burst T0 /CK CK COMMAND READ Bank a, ADDRESS Col RDQS DQ T0 /CK CK COMMAND READ Bank a, ADDRESS Col RDQS n=data-out from column n. NOTE : 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following Shown with nominal t 5 ...

Page 27

... K4J55323QG Consecutive READ Bursts T0 /CK CK COMMAND READ Bank a, ADDRESS Col n RDQS ( data-out from column n (or column b). NOTE : 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following Three subsequent elements of data-out appear in the programmed order following DQ b. ...

Page 28

... K4J55323QG Nonconsecutive READ Bursts T0 /CK CK COMMAND READ Bank a, ADDRESS Col RDQS DQ T0 /CK CK COMMAND READ Bank a, ADDRESS Col RDQS ( data-out from column n (or column b). NOTE : 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following DQ n. ...

Page 29

... K4J55323QG Random READ Accesses T0 /CK CK COMMAND READ Bank a, ADDRESS Col n RDQS DQ T0 /CK CK COMMAND READ Bank a, ADDRESS Col n RDQS ( data-out from column n (or column x or column x or column b or column g). NOTE : 2. Burst length = 4 3. n’ b’ or g’ indicates the next data-out following respectively 4 ...

Page 30

... K4J55323QG READ to WRITE T0 /CK CK COMMAND READ NOP Bank ADDRESS Col n RDQS WDQS Termination data-out from column n. NOTE : data-in from column b. 3. Burst length = 4 4. One subsequent element of data-out appears in the programmed order following Data-in elements are applied following the programmed order. ...

Page 31

... K4J55323QG READ to PRECHARGE T0 /CK CK COMMAND READ Bank a, ADDRESS Col n RDQS DQ T0 /CK CK COMMAND READ Bank a, ADDRESS Col n RDQS DQ NOTE ( data-out from column n (or column b Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following Three subsequent elements of data-out appear in the programmed order following DQ b. ...

Page 32

... K4J55323QG 7.9.3 WRITEs WRITE bursts are initiated with a WRITE command, as shown in Figure. The starting column and bank addresses are provided with the WRITE command, and auto pre- charge is either enabled or disabled for that access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic WRITE commands used in the following illustrations, auto precharge is disabled ...

Page 33

... K4J55323QG WRITE Burst T0 /CK CK COMMAND WRITE NOP Bank a, ADDRESS Col b t (NOM) t DQSS DQSS WDQS (MIN) t DQSS DQSS WDQS (MAX) t DQSS DQSS WDQS data-in for column b. NOTE : 2. Three subsequent elements of data-in are applied in the programmed order following DI b. ...

Page 34

... K4J55323QG Consecutive WRITE to WRITE T0 T1 CK# CK COMMAND WRITE NOP Bank ADDRESS Col b t (NOM) DQSS WDQS etc. = data-in for column b, etc. NOTE : 2. Three subsequent elements of data-in are applied in the programmed order following Three subsequent elements of data-in are applied in the programmed order following DI n. ...

Page 35

... K4J55323QG Nonconsecutive WRITE to WRITE T0 T1 /CK CK COMMAND WRITE NOP Bank, ADDRESS Col b t (NOM) DQSS WDQS etc. = data-in for column b, etc. NOTE : 2. Three subsequent elements of data-in are applied in the programmed order following Three subsequent elements of data-in are applied in the programmed order following DI n. ...

Page 36

... K4J55323QG Random WRITE Cycles T0 T1 /CK CK COMMAND WRITE NOP Bank ADDRESS Col b t (NOM) DQSS WDQS DQ DM NOTE etc. = data-in for column b, etc etc. = the next data - in following DI b. etc., according to the programmed burst order. 3. Programmed burst length = 4 cases shown. ...

Page 37

... K4J55323QG WRITE to READ T0 T1 /CK CK COMMAND WRITE NOP Bank ADDRESS Col (NOM) DQSS DQSS WDQS DQ DM RDQS t t (MIN) DQSS DQSS WDQS DQ DM RDQS t t (MAX) DQSS DQSS WDQS DQ DM RDQS data-in for column b. NOTE : 2. Three subsequent elements of data-in the programmed order following DI b. ...

Page 38

... K4J55323QG WRITE to PRECHARGE T0 T1 /CK CK COMMAND WRITE NOP Bank ADDRESS Col (NOM) DQSS DQSS WDQS (MIN) DQSS DQSS WDQS (MAX) DQSS DQSS WDQS DQ DM NOTE data-in for column Three subsequent elements of data-in the programmed order following DI b. ...

Page 39

... K4J55323QG 7.9.4 PRECHARGE The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access some specified time (t ) after the PRECHARGE command is RP issued. Input A8 determines whether one or all banks are to be precharged, and in the case where only one bank precharged, inputs BA0, BA1 select the bank ...

Page 40

... K4J55323QG 8.0 IBIS : I/V Characteristics for Input and Output Buffers (2) OCD (40 Ω) Pulldown Current (mA) Voltage Minimum (V) 0.1 2.4 0.2 4.7 0.3 7.0 0.4 9.3 0.5 11.5 0.6 13.6 0.7 15.7 0.8 17.7 0.9 19.6 1.0 21.4 1.1 23.2 1.2 24.8 1.3 26.3 1.4 27.7 1.5 29 -10 -15 -20 -25 -30 -35 -40 Maximum 2.8 5.5 8.3 11.0 13.7 16.4 19.0 21.6 24.2 26.7 29.1 31.6 34.0 36.3 38.5 Pull- Voltage ( /53 - 256M GDDR3 SDRAM Pullup Current (mA) Minimum Maximum -2.4 -4.7 -7.0 -9.2 -11.4 -13.4 -15.4 -17.1 -18.8 -20.3 -21.7 -22.9 -23.9 -24.8 -25 Min Max Rev. 1.3 June 2006 -3.1 -6.2 -9.2 -12.1 -14.9 -17.7 -20.3 -22.8 -25.2 -27.5 -29.6 -31.6 -33.3 -34.9 -36.3 ...

Page 41

... K4J55323QG Pull-Down Voltage ( /53 - 256M GDDR3 SDRAM Min Max 13 15 Rev. 1.3 June 2006 ...

Page 42

... K4J55323QG TRUTH TABLE - Clock Enable (CKE) CKEn-1 CKEn CURRENT STATE Power-Down L L Self Refresh Power-Down L H Self Refresh All Banks Idle H L Bank(s) Active All Banks Idle Note : 1. CKEn is the logic state of CKE at clock edge n; CKEn-1was the state of CKE at the previous clock edge. ...

Page 43

... K4J55323QG Read w/ Auto- : Starts with registration of an READ command with auto precharge enabled and ends Precharge Enabled when tRP has been met. Once t Write w/ Auto- : Starts with registration of a WRITE command with auto precharge enabled and ends Precharge Enabled when t has been met. Once The following states must not be interrupted by any executable command ...

Page 44

... K4J55323QG 3. Current state definitions : Idle : The bank has been precharged, and t Row Active : A row in the bank has been activated, and t No data bursts/accesses and no register accesses are in progress. Read : A READ burst has been initiated, with auto precharge disabled. Write : A WRITE burst has been initiated, with auto precharge disabled. ...

Page 45

... K4J55323QG 9.0 COMMANDS Below Truth table-COMMANDs provides a quick reference of available commands. This is followed by a verbal description of each command. Two additional Truth Tables appear following the operation section : these tables provide current state/next state information. TRUTH TABLE - COMMANDs Name (Function) DESELECT (NOP) NO OPERATION (NOP) ...

Page 46

... K4J55323QG READ The READ command is used to initiate a burst read access to an active row. The value on the BA0 and BA1 inputs select the bank, and the address provided on inputs A0-A7, A9 selects the starting column location. The value on input A8 determines whether or not auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the READ burst; if auto pre- charge is not selected, the row will remain open for subsequent accesses ...

Page 47

... K4J55323QG DATA TERMINATION DISABLE (BUS SNOOPING FOR READ COMMAND) The DATA TERMINATOR DISABLE COMMAND is detected by the device by snooping the bus for READ commands excluding /CS. The GDDR3 DRAM will disable its Data terminators when a READ command is detected. The terminators are disable CL-1 Clocks after the READ command is detected ...

Page 48

... K4J55323QG 10.0 AC & DC OPERATING CONDITIONS 10.1 ABSOLUTE MAXIMUM RATINGS Parameter Voltage on any pin relative to Vss Voltage on V supply relative to Vss DD Voltage on V supply relative to Vss DDQ MAX Junction Temperature Storage temperature Power dissipation Short Circuit Output Current Note : Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rat- ing only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied ...

Page 49

... K4J55323QG 10.3 CLOCK INPUT OPERATING CONDITIONS Recommended operating conditions ( Parameter/ Condition Clock Input Mid-Point Voltage ; CK and /CK Clock Input Voltage Level; CK and /CK Clock Input Differential Voltage ; CK and /CK Clock Input Differential Voltage ; CK and /CK Clock Input Crossing Point Voltage ; CK and /CK Note : 1. This provides a minimum of 1.16V to a maximum of 1.36V, and is always 70% of VDDQ 2 ...

Page 50

... K4J55323QG 10.4 DC CHARACTERISTICS Parameter Symbol Operating Current I CC1 (One Bank Active) Precharge Standby Current I P CC2 in Power-down mode Precharge Standby Current I N CC2 in Non Power-down mode Active Standby Current I P CC3 power-down mode Active Standby Current CC3 in Non Power-down mode Operating Current ...

Page 51

... K4J55323QG 10.6 AC CHARACTERISTICS(I-I) Parameter DQS out access time from CK CK high-level width CK low-level width CL=11 CL=10 CK cycle time CL=9 CL=8 CL=7 WRITE Latency DQ and DM input hold time relative to DQS DQ and DM input setup time relative to DQS Active termination setup time Active termination hold time DQS input high pulse width ...

Page 52

... K4J55323QG AC CHARACTERISTICS (II) Parameter Row active time Row cycle time Refresh row cycle time RAS to CAS delay for Read RAS to CAS delay for Write Row precharge time Row active to Row active Last data in to Row precharge (PRE or Auto-PRE) Last data in to Read command ...

Page 53

... K4J55323QG 11.0 PACKAGE DIMENSIONS (FBGA) 0.12 Max 0.45 ± 0.05 0.35 ± 0.05 1.20 Max 256M GDDR3 SDRAM A1 INDEX MARK 14.0 11.0 <Top View> 0.8x11=8.8 0 0.40 <Top View: See the balls through the package> Ball existing Depopulated ball - 53 /53 - ...

Related keywords