IC AMP AUDIO 150W AB 27FLEXIWATT

TDA7575

Manufacturer Part NumberTDA7575
DescriptionIC AMP AUDIO 150W AB 27FLEXIWATT
ManufacturerSTMicroelectronics
TypeClass AB
TDA7575 datasheets
 


Specifications of TDA7575

Output Type1-Channel (Mono) or 2-Channel (Stereo)Max Output Power X Channels @ Load150W x 1 @ 1 Ohm; 75W x 2 @ 2 Ohm
Voltage - Supply8 V ~ 18 VFeaturesDifferential Inputs, I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting TypeThrough HolePackage / Case27-Flexiwatt (bent and staggered leads)
Operational ClassClass-ABOutput Power (typ)150x1@1Ohm/75x2@2OhmW
Audio Amplifier FunctionSpeakerTotal Harmonic Distortion0.02@1Ohm@30W%
Single Supply Voltage (typ)9/12/15VDual Supply Voltage (typ)Not RequiredV
Power Supply RequirementSinglePower Dissipation86W
Rail/rail I/o TypeNoSingle Supply Voltage (min)8V
Single Supply Voltage (max)18VDual Supply Voltage (min)Not RequiredV
Dual Supply Voltage (max)Not RequiredVOperating Temp Range-55C to 150C
Operating Temperature ClassificationMilitaryMountingSurface Mount
Pin Count36Package TypePSOP
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
Page 19/21

Download datasheet (585Kb)Embed
PrevNext
DOCUMENT CD00003142
REVISION 3.0
MULTIPLE FAULTS.
When more misconnections are simultaneously in place at the audio outputs, it is guaranteed that at least one
of them is initially read out. The others are notified after successive cycles of I
provided that the diagnostic is enabled. This is true for both kinds of diagnostic (Turn on and Permanent).
The table below shows all the couples of double-fault possible. It should be taken into account that a short circuit
with the 4 ohm speaker unconnected is considered as double fault.
Double fault table for Turn On Diagnostic
S. GND (sc)
S. GND (sc)
S. GND
S. GND (sk)
S. Vs
S. Across L.
Open L.
S. GND (so) / S. GND (sk) in the above table make a distinction according to which of the 2 outputs is shorted
to ground (test-current source side= so, test-current sink side = sk). More precisely, in both the Channels SO =
CH+, and SK = CH-.
In Permanent Diagnostic the table is the same, with only a difference concerning Open Load(*) , which is not
among the recognisable faults. Should an Open Load be present during the device's normal working, it would
be detected at a subsequent Turn on Diagnostic cycle (i.e. at the successive Car Radio Turn on).
FAULTS AVAILABILITY
All the results coming from I
period of time. If the fault is stable throughout the whole period, it will be sent out. This is true for DC diagnostic
(Turn on and Permanent), for Offset Detector.
To guarantee always resident functions, every kind of diagnostic cycles (Turn on, Permanent, Offset) will be
reactivate after any I2C reading operation. So, when the micro reads the I
but the read data will come from the previous diag. cycle (i.e. The device is in Turn On state, with a short to Gnd,
then the short is removed and micro reads I2C. The short to Gnd is still present in bytes, because it is the result
of the previous cycle. If another I2C reading operation occurs, the bytes do not show the short). In general to
observe a change in Diagnostic bytes, two I2C reading operations are necessary.
2
I
C PROGRAMMING/READING SEQUENCES
A correct turn on/off sequence respectful of the diagnostic timings and producing no audible noises could be as
follows (after battery connection):
– TURN-ON: (STAND-BY OUT + DIAG ENABLE) --- 500 ms (min) --- MUTING OUT
– TURN-OFF: MUTING IN --- 20 ms --- (DIAG DISABLE + STAND-BY IN)
Car Radio Installation: DIAG ENABLE (write) --- 200 ms --- I
– OFFSET TEST: Device in Play (no signal) --
– OFFSET ENABLE - 30ms - I
2
(repeat I
C reading until high-offset message disappears).
Copyright STMicroelectronics
ACTIVE
S. GND (sk)
S. Vs
S. GND
S. Vs + S. GND
/
S. GND
S. Vs
/
/
S. Vs
/
/
/
/
2
Cbus, by read operations, are the consequence of measurements inside a defined
2
C read (repeat until All faults disappear).
2
C reading
COMPANY INTERNAL
DATE 22-Mar-2004
TDA7575PD
2
C reading and faults removal,
S. Across L.
Open L.
S. GND
S. GND
S. GND
Open L. (*)
S. Vs
S. Vs
/
S. Across L.
N.A.
/
/
Open L. (*)
2
C, a new cycle will be able to start,
Unauthorized reproduction and communication strictly prohibited
page: 15/17
15/17