OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vac]
Max. Load Current
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case [R θJC ]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time [msec]
Power Factor (Min.) with Max. Load
Snubber (Internal)
INPUT SPECIFICATIONS 1
Resistor, Variable [Ohms]
GENERAL NOTES
1
2
3
4
5
SERIES RPC.
Rev. 012908
PAGE 1 OF 3
All parameters at 25°C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Potentiometer should be selected with regards to line voltage isolation.
Variable resistance terminals (3,4) are not isolated from output terminals (1,2).
M O D E L
4
3
[Arms]
[msec]
4
N U M B E R S
2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
150K (1W) 150K (1W) 150K (1W)
RPC1215
90-130
400
150
1.48
500
1.6
0.6
yes
15
70
94
10
• Uses Potentiometer for
• Industry Standard Package
Economical Power Control
RPC1225
90-130
1.02
400
250
260
500
1.6
0.6
yes
25
80
10
RPC1240
90-130
1620
400
625
500
1.6
0.6
yes
.63
40
90
10
1M (1/2W) 1M (1/2W) 1M (1/2W)
RPC2415
200-240
1.48
600
150
500
yes
1.6
0.6
15
70
94
7
© 2008 CRYDOM Inc., Specifications subject to change without notice.
15-40Amp • 120/240/480 Vac - OUTPUT
RPC2425
200-240
1.02
600
250
260
500
1.6
0.6
yes
25
80
7
Solid State Proportional Controller
The RPC series proportional controllers
provide a cost effective method of con-
trolling power in many different appli-
cations such as heaters, universal
motors or incandescent lamps. A cus-
tomer provided potentiometer is all that
is required for control. All modules are
supplied with KS100 protective cover.
RPC2440
200-240
1620
600
625
500
1.6
0.6
yes
.63
40
90
7
Series
RPC4815
1M (1/2W) 1M (1/2W) 1M (1/2W)
400-480
1200
1.48
150
500
1.6
0.6
no
15
70
94
3
RPC4825
400-480
1200
RPC
1.02
250
260
500
1.6
0.6
no
25
80
3
RPC4840
400-480
1200
1620
625
500
1.6
0.6
.63
no
40
90
3