AT89C5115 Atmel Corporation, AT89C5115 Datasheet - Page 17

no-image

AT89C5115

Manufacturer Part Number
AT89C5115
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C5115

Flash (kbytes)
16 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
20
Uart
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
0.5
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C5115-RATUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5115-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C5115-UM
Manufacturer:
SANYO
Quantity:
84
Register
4128G–8051–02/08
Table 11. CKCON Register
CKCON (S:8Fh)
Clock Control Register
Note:
Reset Value = x000 0000b
Number
Bit
7
-
7
6
5
4
3
2
1
0
1. This control bit is validated when the CPU clock bit X2 is set; when X2 is low, this bit
has no effect.
Mnemonic Description
WDX2
PCAX2
WDX2
T2X2
T1X2
T0X2
SIX2
Bit
X2
6
-
Reserved
Do not set this bit.
Watchdog Clock
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
Programmable Counter Array Clock
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
Enhanced UART clock (MODE 0 and 2)
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
Timer 2 Clock
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
Timer 1 Clock
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
Timer 0 Clock
Clear to select 6 clock periods per peripheral clock cycle.
Set to select 12 clock periods per peripheral clock cycle.
CPU Clock
Clear to select 12 clock periods per machine cycle (STD mode) for CPU and all
the peripherals.
Set to select 6 clock periods per machine cycle (X2 Mode) and to enable the
individual peripherals ’X2’ bits.
PCAX2
5
(1)
(1)
(1)
SIX2
(1)
4
T2X2
3
(1)
(1)
T1X2
2
T0X2
1
X2
0
17