AT89C51RC Atmel Corporation, AT89C51RC Datasheet - Page 17

no-image

AT89C51RC

Manufacturer Part Number
AT89C51RC
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT89C51RC

Flash (kbytes)
32 Kbytes
Max. Operating Frequency
24 MHz
Cpu
8051-12C
Max I/o Pins
32
Uart
1
Sram (kbytes)
0.5
Operating Voltage (vcc)
4.0 to 6.0
Timers
3
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51RC-24AC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24AI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24AU
Manufacturer:
ATMEL
Quantity:
5 000
Part Number:
AT89C51RC-24AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL
Quantity:
34 960
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL
Quantity:
5 000
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C51RC-24PC
Manufacturer:
ATM
Quantity:
2 900
Part Number:
AT89C51RC-24PI
Manufacturer:
SANYO
Quantity:
12
Part Number:
AT89C51RC-24PI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
15. Programmable Clock Out
1920D–MICRO–6/08
rupt. Note too, that if EXEN2 is set, a 1-to-0 transition in T2EX will set EXF2 but will not cause a
reload from (RCAP2H, RCAP2L) to (TH2, TL2). Thus when Timer 2 is in use as a baud rate gen-
erator, T2EX can be used as an extra external interrupt.
Note that when Timer 2 is running (TR2 = 1) as a timer in the baud rate generator mode, TH2 or
TL2 should not be read from or written to. Under these conditions, the Timer is incremented
every state time, and the results of a read or write may not be accurate. The RCAP2 registers
may be read but should not be written to, because a write might overlap a reload and cause
write and/or reload errors. The timer should be turned off (clear TR2) before accessing the Timer
2 or RCAP2 registers.
A 50% duty cycle clock can be programmed to come out on P1.0, as shown in
pin, besides being a regular I/O pin, has two alternate functions. It can be programmed to input
the external clock for Timer/Counter 2 or to output a 50% duty cycle clock ranging from 61 Hz to
4 MHz at a 16 MHz operating frequency.
To configure the Timer/Counter 2 as a clock generator, bit C/T2 (T2CON.1) must be cleared and
bit T2OE (T2MOD.1) must be set. Bit TR2 (T2CON.2) starts and stops the timer.
The clock-out frequency depends on the oscillator frequency and the reload value of Timer 2
capture registers (RCAP2H, RCAP2L), as shown in the following equation.
In the clock-out mode, Timer 2 roll-overs will not generate an interrupt. This behavior is similar to
when Timer 2 is used as a baud-rate generator. It is possible to use Timer 2 as a baud-rate gen-
erator and a clock generator simultaneously. Note, however, that the baud-rate and clock-out
frequencies cannot be determined independently from one another since they both use
RCAP2H and RCAP2L.
Figure 15-1. Timer 2 in Clock-Out Mode
(T2EX)
P1.0
P1.1
(T2)
OSC
TRANSITION
DETECTOR
Clock-Out Frequency
÷2
EXEN2
=
------------------------------------------------------------------------------------ -
4 x [65536-(RCAP2H,RCAP2L)]
C/T2 BIT
Oscillator Frequency
EXF2
TR2
÷2
TIMER 2
INTERRUPT
(8-BITS)
RCAP2L RCAP2H
TL2
AT89C51RC
T2OE (T2MOD.1)
(8-BITS)
TH2
Figure
15-1. This