ATmega3290P Atmel Corporation, ATmega3290P Datasheet - Page 309

no-image

ATmega3290P

Manufacturer Part Number
ATmega3290P
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATmega3290P

Flash (kbytes)
32 Kbytes
Pin Count
100
Max. Operating Frequency
20 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
69
Ext Interrupts
32
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
1
Uart
1
Segment Lcd
160
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
1024
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATmega3290P-16AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATmega3290P-20AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega3290P-20AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega3290PA-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega3290PA-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega3290PV-10AU
Manufacturer:
SIPEX
Quantity:
17 600
Part Number:
ATmega3290PV-10AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega3290PV-10AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
27.7.13
27.7.14
27.7.15
8021G–AVR–03/11
Reading the Signature Bytes
Reading the Calibration Byte
Parallel Programming Characteristics
Figure 27-6. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 303
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS1 to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
The algorithm for reading the Calibration byte is as follows (refer to
page 303
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
Table 27-15. Parallel Programming Characteristics, V
Symbol
V
I
t
t
t
t
t
t
t
PP
DVXH
XLXH
XHXL
XLDX
XLWL
XLPH
PLXH
PP
for details on Command and Address loading):
for details on Command and Address loading):
Parameter
Programming Enable Voltage
Programming Enable Current
Data and Control Valid before XTAL1 High
XTAL1 Low to XTAL1 High
XTAL1 Pulse Width High
Data and Control Hold after XTAL1 Low
XTAL1 Low to WR Low
XTAL1 Low to PAGEL high
PAGEL low to XTAL1 high
Extended Fuse Byte
Fuse Low Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
CC
ATmega329P/3290P
= 5V ± 10%
BS1
11.5
Min
0
1
200
150
150
67
67
0
0
”Programming the Flash” on
”Programming the Flash” on
Typ
DATA
Max
12.5
250
Units
μA
ns
ns
ns
ns
ns
ns
ns
V
309

Related parts for ATmega3290P