AD7193 Analog Devices, AD7193 Datasheet - Page 23

no-image

AD7193

Manufacturer Part Number
AD7193
Description
4-Channel, 4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC with PGA
Manufacturer
Analog Devices
Datasheet

Specifications of AD7193

Resolution (bits)
24bit
# Chan
4
Sample Rate
n/a
Interface
Ser,SPI
Analog Input Type
Diff-Uni,SE-Uni,Usr-Defined Range/Offset
Ain Range
± (Vref/Gain)
Adc Architecture
Sigma-Delta
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7193BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7193BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7193BRUZ-REEL
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7193BRUZ-REEL
Manufacturer:
ADI原装
Quantity:
20 000
Company:
Part Number:
AD7193BRUZ-REEL
Quantity:
5 000
Part Number:
AD7193BRUZ-SMD
Manufacturer:
TI
Quantity:
5 600
Data Sheet
STATUS REGISTER
RS2, RS1, RS0 = 000; Power-On/Reset = 0x80
The status register is an 8-bit read-only register. To access the
ADC status register, the user must write to the communications
register, select the next operation to be a read operation, and
SR7
RDY(1)
Table 19. Status Register (SR) Bit Designations
Bit
Location
SR7
SR6
SR5
SR4
SR3 to SR0
Bit Name
RDY
ERR
NOREF
Parity
CHD3 to CHD0
SR6
ERR(0)
Description
Ready bit for the ADC. This bit is cleared when data is written to the ADC data register. The RDY bit is set
automatically after the ADC data register is read, or a period of time before the data register is updated,
with a new conversion result to indicate to the user that the conversion data should not be read. It is also
set when the part is placed in power-down mode or idle mode or when SYNC is taken low. The end of a
conversion is also indicated by the DOUT/RDY pin. This pin can be used as an alternative to the status
register for monitoring the ADC for conversion data.
ADC error bit. This bit is written to at the same time as the RDY bit. This bit is set to indicate that the result
written to the ADC data register is clamped to all 0s or all 1s. Error sources include overrange, underrange,
or the absence of a reference voltage. This bit is cleared when the result written to the data register
returns to within the allowed analog input range. The ERR bit is also set during calibrations if the reference
source is invalid or if the applied analog input voltages are outside range during system calibrations.
No external reference bit. This bit is set to indicate that the selected reference (REFIN1 or REFIN2) is at a
voltage that is below a specified threshold. When set, conversion results are clamped to all 1s. This bit is
cleared to indicate that a valid reference is applied to the selected reference pins. The NOREF bit is enabled by
setting the REFDET bit in the configuration register to 1.
Parity check of the data register. If the ENPAR bit in the mode register is set and there is an odd number of
1s in the data register, the parity bit is set. It is cleared if there is an even number of 1s in the data register.
The DAT_STA bit in the mode register should be set when the parity check is used. When the DAT_STA bit
is set, the contents of the status register are transmitted along with the data for each data register read.
These bits indicate which channel corresponds to the data register contents. They do not indicate which
channel is presently being converted but indicate which channel was selected when the conversion
contained in the data register was generated.
SR5
NOREF(0)
SR4
Parity(0)
Rev. C | Page 23 of 56
SR3
CHD3(0)
load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 19 outlines the bit
designations for the status register. SR0 through SR7 indicate the
bit locations, SR denoting that the bits are in the status register.
SR7 denotes the first bit of the data stream. The number in paren-
theses indicates the power-on/reset default status of that bit.
SR2
CHD2(0)
SR1
CHD1(0)
SR0
CHD0(0)
AD7193

Related parts for AD7193