5-860245-1 TE Connectivity, 5-860245-1 Datasheet - Page 3

5-860245-1

Manufacturer Part Number
5-860245-1
Description
Manufacturer
TE Connectivity
Datasheet

Specifications of 5-860245-1

Product Type
Flying Lead Assembly
Product Style
Cable Assembly
Shape
Circular
Prewired
Yes
Mount Angle
Straight
Wire Size (mm² [awg])
0.5-0.6² [20]
Flange
With
Operating Voltage (kvdc)
15
Shielded
No
Number Of Positions
7
Mount Type
Bulkhead
Boot
Without
Lead Assembly Type
Connector with flying leads.
Assembly Length (mm [in])
304.80 [12.000]
Wire Insulation
Silicone
Connector Style
Receptacle
Housing Material
Epoxy
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Rev O2
Vibration, sinusoidal.
Mechanical shock.
Durability.
Contact engaging force.
Contact separating force.
Therm al shock.
Hum idity, steady state.
Tem perature life.
Test Description
No discontinuities of 10
m icroseconds or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
20 ounces m axim um .
3 ounces m inim um .
See Note.
See Note.
See Note.
ENVIRONMENTAL
MECHANICAL
Figure 1 (cont)
Requirem ent
EIA-364-28, Test Condition I.
Subject m ated specim ens to 10-55-
10 Hz traversed in 1 m inute with 1.5
m m [.06 in] m axim um total
excursion. 2 hours in each of 3
m utually perpendicular planes.
EIA-364-27, Method H.
Subject m ated specim ens to 30 G's
half-sine shock pulses of 11
m illiseconds duration. 3 shocks in
each direction applied along 3
m utually perpendicular planes, 18
total shocks.
EIA-364-9.
Mate and unm ate gold plated
specim ens for 500 cycles and tin
plated specim ens for 50 cycles at a
m axim um rate of 500 cycles per
hour.
AMP Spec 109-35.
Measure force necessary to
engage using gage 2 to a depth of
.19 inch for 1/2I and 1/2LI and .25
inch for 1I, 1LI, 2I, 3I and 4I.
See Figure 4.
AMP Spec 109-35.
Size 3 tim es using gage 2. Then
insert gage 1 to depth of .19 inch
for 1/2I and 1/2LI and .25 inch for
1I, 1LI, 2I, 3I and 4I and m easure
force necessary to separate.
See Figure 4.
EIA-364-32.
Subject specim ens to 5 cycles
between -55 and 125 C.
EIA-364-31, Method II, Condition A.
Subject specim ens to 40 C and 90
to 95% RH for 96 hours.
EIA-364-17, Method A, Test
Condition 5, Test Tim e Condition A.
Subject m ated specim ens to 125 C
for 96 hours.
Procedure
108-36033
3 of 6

Related parts for 5-860245-1