EP4CE15E22C8
EP4CE15E22C8 | |
|---|---|
| Manufacturer Part Number | EP4CE15E22C8 |
| Description | IC CYCLONE IV FPGA 15K 144EQFP |
| Manufacturer | Altera Corporation |
| Series | CYCLONE® IV E |
| EP4CE15E22C8 datasheets |
|
Availability: In stock
International delivery:
Warranty: 60 days
×
- We provide standard 60-days warranty for all parts. If warranty differs we always mention it beforehand. In case of return we cover shipping costs.
- If you still have any questions - please contact us
×
Shipping terms
- Standard delivery time differs from 5-8 business days if the supplier is a local one to 12-14 days if the suplier is from overseas. If delivery time differs it's always mentioned in our quotation.
- We ship worldwide using main international couriers like FedEx, DHL, UPS, TNT, EMS. We can also use client's freight account. Other shipping methods can be discussed. We do best to meet your needs!
Payment terms
- For new client payment term is payment in advance. At this moment we accept 3 payment methods: wire transfer, PayPal and Western Union. Credit card payment is under constrution and will be introduced soon. Escrow service is acceptable. Net terms for regular customers is not a problem. Working with us is totally safe for you.
- If you still have any questions - please contact us
Specifications of EP4CE15E22C8 | |||
|---|---|---|---|
| Number Of Logic Elements/cells | 15408 | Number Of Labs/clbs | 963 |
| Total Ram Bits | 516096 | Number Of I /o | 81 |
| Number Of Gates | - | Voltage - Supply | 1.15 V ~ 1.25 V |
| Mounting Type | Surface Mount | Operating Temperature | 0°C ~ 85°C |
| Package / Case | 144-LQFP Exposed Pad | Lead Free Status | Contains lead |
| Rohs Status | RoHS non-compliant | ||
PrevNext
1–6
Table 1–4. Recommended Operating Conditions for Cyclone IV GX Devices (Part 2 of 2)—Preliminary
Symbol
Parameter
V
Transceiver output buffer power supply
CCH_GXB
Transceiver PMA and auxiliary power
V
CCA_GXB
supply
Transceiver PMA and auxiliary power
V
CCL_GXB
supply
V
DC input voltage
I
V
DC output voltage
O
T
Operating junction temperature
J
t
Power supply ramp time
RAMP
Magnitude of DC current across
I
Diode
PCI-clamp diode when enabled
Notes to
Table
1–4:
(1) All VCCA pins must be powered to 2.5 V (even when PLLs are not used) and must be powered up and powered down at the same time.
(2) You must connect V
to V
through a decoupling capacitor and ferrite bead.
CCD_PLL
CCINT
(3) Power supplies must rise monotonically.
(4) V
for all I/O banks must be powered up during device operation. Configurations pins are powered up by V
CCIO
I/O Banks 3 and 9 only support V
of 1.5, 1.8, 2.5, 3.0, and 3.3 V. For fast passive parallel (FPP) configuration mode, the V
CCIO
Bank 8 must be powered up to 1.5, 1.8, 2.5, 3.0, and 3.3 V.
(5) You must set V
to 2.5 V if you use CLKIN as a high-speed serial interface (HSSI) refclk or as a DIFFCLK input.
CC_CLKIN
(6) The CLKIN pins in I/O Banks 3B and 8B can support single-ended I/O standard when the pins are used to clock left PLLs in non-transceiver
applications.
(7) The POR time for Standard POR ranges between 50 and 200 ms. V
operating range within 50 ms.
(8) The POR time for Fast POR ranges between 3 and 9 ms. V
range within 3 ms.
ESD Performance
This section lists the electrostatic discharge (ESD) voltages using the human body
model (HBM) and charged device model (CDM) for Cyclone IV devices general
purpose I/Os (GPIOs) and high-speed serial interface (HSSI) I/Os.
ESD for Cyclone IV devices GPIOs and HSSI I/Os.
Table 1–5. ESD for Cyclone IV Devices GPIOs and HSSI I/Os
Symbol
ESD voltage using the HBM (GPIOs)
V
ESDHBM
ESD using the HBM (HSSI I/Os)
ESD using the CDM (GPIOs)
V
ESDCDM
ESD using the CDM (HSSI I/Os)
Notes to
Table
1–5:
(1) The passing voltage for EP4CGX15 and EP4CGX30 row I/Os is ±1000V.
(2) This value is applicable only to Cyclone IV GX devices.
Cyclone IV Device Handbook,
Volume 3
Conditions
—
—
—
—
—
For commercial use
For industrial use
- on reset
Standard power
(7)
(POR)
(8)
Fast POR
—
, V
, and V
of I/O Banks 3, 8, and 9 must reach the recommended
CCINT
CCA
CCIO
, V
, and V
of I/O Banks 3, 8, and 9 must reach the recommended operating
CCINT
CCA
CCIO
Parameter
Passing Voltage
(1)
(2)
(2)
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
Min
Typ
Max
Unit
2.375
2.5
2.625
V
2.375
2.5
2.625
V
1.16
1.2
1.24
V
–0.5
—
3.6
V
0
—
V
V
CCIO
0
—
85
°C
–40
—
100
°C
50 µs
—
50 ms
—
50 µs
—
3 ms
—
—
—
10
mA
of I/O Banks 3, 8, and 9 where
CCIO
level of I/O
CCIO
Table 1–5
lists the
Unit
± 2000
V
± 1000
V
± 500
V
± 250
V
November 2011 Altera Corporation
Related parts for EP4CE15E22C8 | |||
|---|---|---|---|
| Part Number | Description | Manufacturer | Datasheet |
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 144EQFP | Altera Corporation |
|
|
|
IC CYCLONE IV E FPGA 15K 484FBGA | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 256FBGA | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 256FBGA | Altera Corporation |
|
|
|
IC CYCLONE IV FPGA 15K 256FBGA | Altera Corporation |
|