STM32F100C6 STMicroelectronics, STM32F100C6 Datasheet - Page 63

no-image

STM32F100C6

Manufacturer Part Number
STM32F100C6
Description
Mainstream Value line, ARM Cortex-M3 MCU with 32 Kbytes Flash, 24 MHz CPU, motor control and CEC functions
Manufacturer
STMicroelectronics
Datasheet

Specifications of STM32F100C6

Peripherals Supported
timers, ADC, SPIs, I2Cs, USARTs and DACs
Conversion Range
0 to 3.6 V
16-bit, 6-channel Advanced-control Timer
up to 6 channels for PWM output, dead time generation and emergency stop
Systick Timer
24-bit downcounter

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STM32F100C6
Manufacturer:
ST
0
Part Number:
STM32F100C6T6
Manufacturer:
ST
0
Part Number:
STM32F100C6T6
Manufacturer:
ST/意法
Quantity:
990
Part Number:
STM32F100C6T6B
Manufacturer:
ST
Quantity:
1 400
Part Number:
STM32F100C6T6B
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STM32F100C6T6B
Manufacturer:
ST
0
Part Number:
STM32F100C6T6B
Manufacturer:
ST
Quantity:
20 000
Part Number:
STM32F100C6T6B
Manufacturer:
ST/意法
Quantity:
18 000
Part Number:
STM32F100C6T6B
0
Part Number:
STM32F100C6T6BTR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STM32F100C6T6BTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
STM32F100C6T6BTR
0
STM32F100x4, STM32F100x6, STM32F100x8, STM32F100xB
Table 39.
1. Guaranteed by design, not tested in production.
2. f
3. The maximum hold time of the Start condition only has to be met if the interface does not stretch the low
4. The device must internally provide a hold time of at least 300 ns for the SDA signal in order to bridge the
t
w(STO:STA)
Symbol
t
t
t
t
t
w(SCLH)
t
w(SCLL)
t
su(SDA)
t
t
t
su(STO)
t
su(STA)
h(SDA)
4 MHz to achieve fast mode I
maximum I2C fast mode clock.
period of SCL signal.
undefined region of the falling edge of SCL.
h(STA)
r(SDA)
r(SCL)
f(SDA)
f(SCL)
PCLK1
C
b
must be higher than 2 MHz to achieve standard mode I
SCL clock low time
SCL clock high time
SDA setup time
SDA data hold time
SDA and SCL rise time
SDA and SCL fall time
Start condition hold time
Repeated Start condition setup
time
Stop condition setup time
Stop to Start condition time (bus
free)
Capacitive load for each bus line
I
2
C characteristics
Parameter
2
C frequencies. It must be a multiple of 10 MHz to reach the 400 kHz
Doc ID 16455 Rev 6
Standard mode I
Min
250
0
4.7
4.0
4.0
4.7
4.0
4.7
(3)
2
C frequencies. It must be higher than
1000
Max
300
400
2
C
(1)
Electrical characteristics
Fast mode I
Min
100
0
1.3
0.6
0.6
0.6
1.3
0.6
(4)
2
900
Max
C
300
300
400
(1)(2)
(3)
Unit
63/87
pF
µs
ns
µs
µs
µs

Related parts for STM32F100C6