VIPER27 STMicroelectronics, VIPER27 Datasheet - Page 25

no-image

VIPER27

Manufacturer Part Number
VIPER27
Description
VIPerPlus family: fixed frequency high performance off line high voltage converter
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VIPER27
Manufacturer:
ST
0
Part Number:
VIPER27H
Manufacturer:
TI
Quantity:
121
Part Number:
VIPER27H
Manufacturer:
ST
0
Part Number:
VIPER27HD
Manufacturer:
MPS
Quantity:
10 000
Part Number:
VIPER27HD
Manufacturer:
ST
0
Part Number:
VIPER27HDTR
Manufacturer:
ST
0
Part Number:
VIPER27HN
Manufacturer:
ST
Quantity:
4 500
Part Number:
VIPER27HN
Manufacturer:
ST
Quantity:
23 994
Part Number:
VIPER27HN
Manufacturer:
ST
0
Part Number:
VIPER27L
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER27LD
Manufacturer:
STMicroelectronics
Quantity:
1 935
Part Number:
VIPER27LD
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER27LDTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER27LDTR
0
Part Number:
VIPER27LN
Manufacturer:
ST
Quantity:
2 500
Part Number:
VIPER27LN
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER27LN
Manufacturer:
ST
Quantity:
3 997
VIPER27
7.13
2
The
secondary winding or a hard-saturation of fly-back transformer. Such as anomalous
condition is invoked when the drain current exceed the threshold I
page 7
To distinguish a real malfunction from a disturbance (e.g. induced during ESD tests) a
“warning state” is entered after the first signal trip. If in the subsequent switching cycle the
signal is not tripped, a temporary disturbance is assumed and the protection logic will be
reset in its idle state; otherwise if the I
switching cycles a real malfunction is assumed and the power MOSFET is turned OFF.
The shutdown condition is latched as long as the device is supplied. While it is disabled, no
energy is transferred from the auxiliary winding; hence the voltage on the V
decays till the V
The start up HV current generator is still off, until V
V
and the converter switching restarts if the V
the device enters in auto-restart mode. This behavioral results in a low-frequency
intermittent operation (Hiccup-mode operation), with very low stress on the power circuit.
See the timing diagram of
Figure 32. Hiccup-mode OCP: timing diagram
DD(RESTART)
V
nd
DD
VIPER27
(RESTART)
I
V
DRAIN
level over current protection and hiccup mode
V
Vcc
V
DRAIN
V
.
DD
DD
I
DMAX
DD
on
off
is protected against short circuit of the secondary rectifier, short circuit on the
. After this condition the V
DD
under voltage threshold (V
Secondary diode is shorted here
Secondary diode is shorted here
Figure 32
Doc ID 15133 Rev 5
.
DMAX
DD
capacitor is charged again by 600 µA current,
DDon
threshold is exceeded for two consecutive
DDoff
occurs. If the fault condition is not removed
), which clears the latch.
DD
voltage goes below its restart voltage,
DMAX
Operation descriptions
, see
DD
Table 8 on
capacitor
25/31
t
t
t
t
t
t

Related parts for VIPER27