ISP 452 Infineon Technologies, ISP 452 Datasheet
ISP 452
Specifications of ISP 452
Related parts for ISP 452
ISP 452 Summary of contents
Page 1
... N channel vertical power FET with charge pump, ground referenced CMOS compatible input, monolithically integrated in Smart SIPMOS ® technology. • Providing embedded protection functions With resistor R GND =150 Ω in GND connection, resistor in series with IN connections, reverse load current limited by connected load. Page ISP 452 2006-03-01 ...
Page 2
... Level shifter ind. loads Rectifier Logic GND 2 Signal GND Function Protected high-side power output Logic ground Input, activates the power switch in case of logical high signal Positive power supply voltage Page 2 ISP 452 + OUT 1 Temperature sensor Load MINI-PROFET Load GND 2006-03-01 ...
Page 3
... Device on epoxy pcb 1.5 mm with copper area for V self-limited = 150°C j, start = 13 PIN 3 PIN 1,2 °C A chip - soldering point: chip - ambient connection Page 3 ISP 452 Symbol Values Unit L(SC -5.0... ± 0 ...
Page 4
... V t OUT off dV /dt -dV/ IN(T -40...+150° IN(T -40...+150°C j ∆V IN( 1 IN(off) IN(off -40...+150° 3 IN(on) bb IN(on -40...+150° Page 4 ISP 452 Values min typ max -- 0.16 0 0.4 0 100 -- 60 150 -- off -3 3.5 1 ...
Page 5
... T =-40...+150° bb(over) T =-40...+150° bb(o rst) ∆V T =-40...+150°C j bb(over) =-40...+150° bb(off GND T =-40...+25° L(off) T =150°C j Page 5 ISP 452 Values Unit min typ max 5 3 6.5 V 7 ...
Page 6
... Requires 150 Ω resistor in GND connection. Reverse load current (through intrinsic drain-source diode) has to be limited by the connected load. Symbol T = 25° L(SC -40...+150°C j =-40...+150° bb(AZ) V ON(CL ∆ 0 ∫ V ON(CL (t) dt, approx. Page 6 ISP 452 Values Unit min typ max 0.7 1 0 150 -- -- ° 0 ...
Page 7
... [°C] Typ. input current 13 [µ 100 125 150 T j [°C] Page 7 ISP 452 150°C 25°C -40° [V] -40°C +25°C +150° ...
Page 8
... T j [°C] Short circuit current I L(SC 13 L(SC) [A] 1.4 1.2 1 0.8 0.6 0.4 0.2 0 -50 -25 100 125 150 T j [°C] Page 8 ISP 452 +150°C +25°C -40°C 50 100 150 200 250 300 350 400 100 125 150 2006-03-01 t [ms [°C] ...
Page 9
... Figure 6: Undervoltage restart of charge pumpe V [ bb(under) 100 125 150 T j [°C] charge pump starts at V Terms [V] Page 9 ISP 452 V bb(over about 5.6 V typ. bb(ucp) 2006-03-01 [V] ...
Page 10
... Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life. If they fail reasonable to assume that the health of the user or other persons may be endangered. Page 10 ISP 452 2006-03-01 ...