NCSE119A Nichia, NCSE119A Datasheet - Page 17

no-image

NCSE119A

Manufacturer Part Number
NCSE119A
Description
Manufacturer
Nichia
Datasheet

Specifications of NCSE119A

Size Lxwxh (mm)
3.5x3.5x2.0
Lumi-nous Inten-sity Typ(cd)
31
Lumi-nous Flux Typ(lm))
98.0
Forward Voltage Vf(v) Typ
3.50
Forward Voltage Vf(v) Max
4.00
Directivity (degree)
120
If (ma)
350
Mounting Style
Through Hole
(7) Cleaning
(8) Eye Safety
(9) Others
● If required, isopropyl alcohol (IPA) should be used. Other solvents may cause premature failure to the LEDs
● Ultrasonic cleaning is not recommended since it may have adverse effects on the LEDs
● In 2006, the International Electrical Commission (IEC) published IEC 62471:2006 Photobiological safety of lamps
● Viewing a flashing light may cause eye discomfort. When incorporating the LED into your product,
● The LEDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,
● The customer shall not reverse engineer by disassembling or analysis of the LEDs without having prior written consent
● Both the customers and Nichia will agree on official specifications of supplied products before a customer's volume production.
● Specifications and appearance subject to change for improvement without notice.
due to the damage to the resin portion. The effects of such solvents should be verified prior to use.
In addition, the use of CFCs such as Freon is heavily regulated.
depending on the ultrasonic power and how LED is assembled.
If ultrasonic cleaning must be used, the customer is advised to make sure the LEDs will not be damaged prior to cleaning.
and lamp systems, which added LEDs in its scope.
On the other hand, the IEC 60825-1:2007 laser safety standard removed LEDs from its scope.
However, please be advised that some countries and regions have adopted standards
based on the IEC laser safety standard IEC 60825-1:20112001, which still includes LEDs in its scope.
Most of Nichia's LEDs can be classified as belonging into either the Exempt Group or Risk Group 1.
High-power LEDs, that emit light containing blue wavelengths, may be classified as Risk Group 2.
Please proceed with caution when viewing directly any LEDs driven at high current, or viewing LEDs
with optical instruments which may greatly increase the damages to your eyes.
please be careful to avoid adverse effects on the human body caused by light stimulation.
communications equipment, measurement instruments and household appliances).
Consult Nichia's sales staff in advance for information on the applications in which exceptional quality
and reliability are required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or
health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control system, automobiles,
traffic control equipment, life support systems and safety devices).
from Nichia. When defective LEDs are found, the customer shall inform Nichia directly before disassembling or analysis.
16