APL111-23486-2 Airpax Corporation, APL111-23486-2 Datasheet

no-image

APL111-23486-2

Manufacturer Part Number
APL111-23486-2
Description
Circuit Breaker, Magnetic Circuit Breakers
Manufacturer
Airpax Corporation
Datasheet

Related parts for APL111-23486-2

APL111-23486-2 Summary of contents

Page 1

...

Page 2

Magnetic Circuit Breakers Multi-Pole Circuit Breakers APL/UPL, 205/295 Barriers Configurations Operating Characteristics Delay Curves Specifications APL/UPL Decision Tables 205/295 Decision Tables 129 130 131 132 134 135 140 146 148 ...

Page 3

INTRODUCTION The APL/UPL magnetic circuit breaker provides reliable, low-cost power switching, circuit protection and circuit control. The handle opens and closes a circuit, under normal load conditions, similar to an ON-OFF switch. Upon over- load, the internal mechanism trips, opens ...

Page 4

APL/UPL, 205/295 MULTI-POLE CIRCUIT BREAKERS Multi-Pole Circuit Breakers Multi-pole breakers are combined in an assembly with the actuating handles linked and the trip mechanisms internally coupled. A fault in either protected circuit opens all poles simultaneously. Applications include use in ...

Page 5

Barriers There are three barrier styles available for the 205/295, 215/285 breakers. Barrier style “B” is supplied for voltages between 200Vac and 250Vac inclusive. Barrier style “D” is required for voltages above 250Vac. Barrier style “C” is available for voltages ...

Page 6

APL/UPL, 205/295 CONFIGURATIONS Series Trip The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indi- cates circuit status. In addition ...

Page 7

Series Trip (See Note A) .625 ± .031 .281 ± .020 .281 ± .020 (15.88 ± 0.79) (7.14 ± 0.51) (7.14 ± 0.51) 1.940 [49.28] LINE LOAD ( 50 AMP) Series Trip with Auxiliary Switch 1.290 ± .031 (32.77 ± ...

Page 8

APL/UPL, 205/295 OPERATING CHARACTERISTICS Inrush Pulse Tolerance (typ) The following table provides a comparison of inrush pulse tolerance with and without the inertial delay feature for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of ...

Page 9

Delay Curves (typ) A choice of delays are offered for 60Hz applications. Delays 60 and 69 are fast acting non-delayed tripping to protect sensitive electronic equipment (not recommended where known inrush exists). Delay 61 has a short delay for ...

Page 10

APL/UPL, 205/295 DELAY CURVES Delays 64, 65 and 66 Delays 64, 65 and 66 are the latest 50/60Hz delays with short, medium and long trip times respectively. The patented breaker design provides both increased tolerance to high inrush induced nuisance ...

Page 11

DC/50/60Hz Delay Curves (typ) (Multi-frequency) A choice of delays is offered for combined DC and 50/60Hz operation. Delay 70 is fast acting, non-delayed tripping to protect sensitive electronic equipment (not recommended where known inrush exists). Delay 71 has a short ...

Page 12

APL/UPL, 205/295 DELAY CURVES DC Delay Curves (typ) A choice of delays is offered for DC applications. Delays 50 and 59 provide fast acting, non-delayed tripping to protect sensitive electronic equipment (not recommended where known inrush exists). Delay 51 has ...

Page 13

Delay Curves (typ) A choice of delays is offered for 400Hz applications. Delays 40 and 49 are fast acting, non-delayed tripping to protect sensitive electronic equipment (not recom- mended where known inrush exists). Delay 41 has a short delay ...

Page 14

APL/UPL SPECIFICATIONS Trip Free Will trip open on overload, even when the handle is forcibly held on or restrained. This prevents operator from damaging the circuit by holding the handle in the ON position. Trip Indication The operating handle moves ...

Page 15

Coil Impedance DC Delays Current Resistance in Ohms Ratings in Amperes 51- .050 162. 540. 506. .100 35.4 105. 125. .500 1.2 4.2 4.5 1. .236 1.02 1.20 5. .021 .048 .059 10. .0060 .0121 .0140 .0040 ...

Page 16

SPECIFICATIONS Trip Free Will trip open on overload, even when the handle is forcibly held on or restrained. This prevents operator from damaging the circuit by holding the handle in the ON position. Trip Indication The operating handle moves ...

Page 17

Ratings Configurations Current Ratings (Amperes) 0.050 - 50 0.050 - 100 0.050 - 60 0.050 - 50 Series and 0.050 - 30 Shunt 0.050 - 50 0.050 - 0.050 - 20 0.050 - 30 Series Only ...

Page 18

MPL SPECIFICATIONS Auxiliary Switch Ratings (APL/UPL, 205/295) REC4 and REC5 are rated at 10 amperes, 250Vac or 3 amperes, 50Vdc. REG4 and REG5 are rated at 0.1 amperes, 125Vac. Moisture Resistance Designed to meet the requirements of MIL-PRF-55629 when ...

Page 19

Approximate Weight Per Pole Ounces Grams 3.7 103 Recommended Torque Specifications 6-32 mounting inserts 6-8 inch pounds M3 mounting inserts 4-5 inch pounds 10-32 stud terminals 13-14 inch pounds M5 stud terminals 13-14 inch pounds ⁄/¢-28 stud terminals 25-30 inch ...

Page 20

APL/UPL DECISION TABLES How to Order The ordering code for APL/UPL circuit breakers may be determined by following the steps in the decision tables shown here. The coding given permits a self-assigning part number; other configurations may require a factory ...

Page 21

Decision First Type APL Magnetic circuit breaker in a molded phenolic case UL and CSA recognized as UPL a component-appliance control UL and CSA recognized as a MPL “manual across the line starter” 2 Second Decision Poles 0* Switch ...

Page 22

DECISION TABLES How to Order The ordering code for 205/295 circuit breakers may be determined by following the steps in the decision tables shown here. For example, the code shown is the code for a UL recognized, two pole ...

Page 23

Fourth Decision Hz and Delay 40* 400Hz 150% instant trip 41* 400Hz short delay 42* 400Hz long delay 43* 400Hz motor start 49* 400Hz 130% instant trip 50 DC 150% instant trip 51 DC short delay 52 DC long ...