1 831
DATA SHEET
PMC-920526
Register 2FH, 4FH, 6FH: TU #2 in TUG2 #1 to TUG2 #7
This register is used to identify and acknowledge loss of pointer interrupts for the
tributaries TU #2 in TUG2 #1 TO TUG2 #7.
LOP1I-LOP7I:
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
The LOP1I to LOP7I bits identify the source of loss of pointer interrupts. In
TU3 mode, these bits are unused and will return a logic 0 when read. When
the corresponding TUG2 tributary group is configured for TU2 (VT6) mode,
the associated LOP x I bit is unused and will return a logic 0 when read. When
operational, the LOP1I to LOP7I bits report and acknowledge LOP interrupts
of TU #2 in TUG2 #1 to TUG2 #7, respectively. Interrupts are generated upon
loss of pointer and upon re-acquisition. An LOP x I bit is set high when a loss
of pointer event on the associated tributary occurs and are cleared
immediately following a read of this register, which also acknowledges and
clears the interrupt. LOP x I remains valid when interrupts are not enabled
(LOPE set low) and may be polled to detect loss of pointer events.
Type
R
R
R
R
R
R
R
ISSUE 8
Function
Unused
LOP7I
LOP6I
LOP5I
LOP4I
LOP3I
LOP2I
LOP1I
Default
X
0
0
0
0
0
0
0