PM5381-BI PMC-Sierra, Inc., PM5381-BI Datasheet - Page 261

no-image

PM5381-BI

Manufacturer Part Number
PM5381-BI
Description
ATM UNI, Single Channel ATM PHY Interface for 2488.32Mbps
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5381-BI-P
Quantity:
119
Part Number:
PM5381-BI-P
Quantity:
6
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2000489, Issue 4
Indirect Register 06H: RHPP Path BIP Error Counter
The RHPP Path BIP Error Counter register is provided at RHPP r/w indirect address 06H.
PBIPE[15:0]
Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
The path BIP error (PBIPE[15:0]) bits represent the number of path BIP errors that have been
detected in the B3 byte since the last accumulation interval. The error counters are
transferred to the holding registers by a microprocessor write to the RHPP Counters Update
register (Address 203H, 283H, 303H, 383H). The TIP output indicates the transfer status.
Type
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Function
PBIPE[15]
PBIPE[14]
PBIPE[13]
PBIPE[12]
PBIPE[11]
PBIPE[10]
PBIPE[9]
PBIPE[8]
PBIPE[7]
PBIPE[6]
PBIPE[5]
PBIPE[4]
PBIPE[3]
PBIPE[2]
PBIPE[1]
PBIPE[0]
S/UNI-2488 Telecom Standard Product Datasheet
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Released
261