BUSY
The active high read and active low write (RWB) bit selects if the current access to an
internal register is an indirect read or an indirect write. Writing to the Indirect Address
Register initiates an access to a register. When RWB is set to logic 1, an indirect read access
to a register is initiated. The data from the addressed location as indicated using the IADDR
field will be transferred to the Indirect Data Register. When RWB is set to logic 0, an indirect
write access to a register is initiated. The data from the Indirect Data Register will be
transferred to the addressed register.
The active high busy (BUSY) bit reports if a previously initiated indirect access to an internal
register has been completed. BUSY is set to logic 1 upon writing to the Indirect Address
Register. BUSY is set to logic 0 upon completion of the access. This register should be
polled to determine when new data is available in the Indirect Data Register.