PM4328-PI PMC-Sierra, Inc., PM4328-PI Datasheet - Page 192

no-image

PM4328-PI

Manufacturer Part Number
PM4328-PI
Description
Framer, T1|E1|T3 Standard Format, 324-BGA
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM4328-PI
Manufacturer:
PMC
Quantity:
22
Part Number:
PM4328-PI
Manufacturer:
ATMEL
Quantity:
320
STANDARD PRODUCT
DATASHEET
PMC-2011596
PROPRIETARY AND CONFIDENTIAL
Update-IR
The update instruction register state is used to load a new instruction into the
instruction register. The new instruction must be scanned in using the Shift-IR
state. The load occurs on the falling edge of TCK.
The Pause-DR and Pause-IR states are provided to allow shifting through the
test data and/or instruction registers to be momentarily paused.
Boundary Scan Instructions
The following is a description of the standard instructions. Each instruction
selects a serial test data register path between input, TDI and output, TDO.
BYPASS
The bypass instruction shifts data from input, TDI to output, TDO with one TCK
clock period delay. The instruction is used to bypass the device.
EXTEST
The external test instruction allows testing of the interconnection to other
devices. When the current instruction is the EXTEST instruction, the boundary
scan register is placed between input, TDI and output, TDO. Primary device
inputs can be sampled by loading the boundary scan register using the
Capture-DR state. The sampled values can then be viewed by shifting the
boundary scan register using the Shift-DR state. Primary device outputs can be
controlled by loading patterns shifted in through input TDI into the boundary scan
register using the Update-DR state.
SAMPLE
The sample instruction samples all the device inputs and outputs. For this
instruction, the boundary scan register is placed between TDI and TDO.
Primary device inputs and outputs can be sampled by loading the boundary scan
register using the Capture-DR state. The sampled values can then be viewed by
shifting the boundary scan register using the Shift-DR state.
IDCODE
The identification instruction is used to connect the identification register
between TDI and TDO. The device's identification code can then be shifted out
using the Shift-DR state.
ISSUE 1
179
HIGH DENSITY T1/E1 FRAMER
AND M13 MULTIPLEXER
PM4328 TECT3

Related parts for PM4328-PI