EFE300 Lambda Electronics, EFE300 Datasheet

no-image

EFE300

Manufacturer Part Number
EFE300
Description
300w / 400w, 3 X 5? / 3 X 6? Power Supplies
Manufacturer
Lambda Electronics
Datasheet
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Input Frequency
Inrush Current
Power Factor Harmonics
Voltage Setting Range
Voltage Setting Accuracy
Total Regulation
Ripple & Noise
Efficiency
Minimum Load
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Fan Supply
Remote Sense
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Isolation
Vibration (non operating)
Shock
Safety Agency Approvals*
Immunity
Conducted Emissions & Flicker
Radiated Emissions
Weight (open frame or enclosed)
Size (Open frame style)
Warranty
(1) Including underside component leads
Full Digital Control
High Efficiency
Low Profile
Power Factor Corrected
(3)
(2)
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
EFE300 & EFE400
mm
mA
mV
ms
yrs
A
A
V
g
-
-
2G, 10-500Hz (sweep & endurance at resonance) in all 3 planes. MIL-STD-810E, Method 516.5, Pro I, IV , V
Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC
UL60950-1, CSA22.2 No 60950-1, EN60950-1, EN61010-1, IEC61010-1, CE for LVD
30G per IEC68-2-27, MIL-STD-810E, Method 514.4, Pro 1, Cat 1, 9.
300W / 400W, 3 x 5” / 3 x 6” Power Supplies
< 4% with 90 - 264VAC input change and 0-100% load change
EN55011, EN55022 Class B (per CISPR.11/22), EN61000-3-3
Forced air, 2m/s from input to output (approximately 10CFM)
0 to +70°C. Derate linearily to 50% load from 50°C to 70°C
317g or 540g
3 x 5 x 1.34"
EFE300
<20A
EN55011, EN55022 Class B (per CISPR.11/22)
12V 0.25A (Available if no fan option selected)
EN61000-4-2, -3, -4, -5, -6, -8, -11, -12, -14
Automatic recovery upon overload removal
-5% to +10% (Chosen at time of ordering)
Benefit
EN61000-3-2 Compliant (0.97 typical)
Broadcast
Test & Measurement
Network servers and routers
47 - 63Hz, 440Hz with reduced PFC
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
>16ms at 90VAC input, 75% load
Improved product performance
Less heat dissipated in system
Fits in 1U enclosures
Supports Global Use
(2) -20°C cold start
(3) At 25°C, 230VAC and cold start
High Efficiency
Active Power Factor Correction
Universal Input (90 - 265VAC)
High peak loading capability
Suitable for 1U applications
90 - 264VAC, 120 - 350VDC
1.5mA at 264VAC, 63Hz
Cycle AC line to reset
±1% at 50% load
-40 to +85°C
<1.5% pk-pk
90% typical
5 - 95% RH
Three Years
None
None
Yes
405g or 635g
3 x 6 x 1.34"
EFE400
<30A

Related parts for EFE300

EFE300 Summary of contents

Page 1

... EFE300 & EFE400 Feature Full Digital Control High Efficiency Low Profile Power Factor Corrected ITEMS Input Voltage range Input Frequency Inrush Current (3) A Power Factor Harmonics ...

Page 2

... EFE300 & EFE400 Product Part Code Description U2Y002G EFE300-12-CNMDS U2Y003H EFE300-12-ECMDS U4Y002H EFE400-12-CNMDS U4Y003J EFE400-12-ECMDS U2Y005K EFE300-24-CNMDS U2Y006L EFE300-24-ECMDS U4Y005L EFE400-24-CNMDS U4Y006M EFE400-24-ECMDS (3) For up to 10s without exceeding Average Output Power rating ...

Related keywords