NL50 Martek Power, NL50 Datasheet

no-image

NL50

Manufacturer Part Number
NL50
Description
Nl50series 50w Output Power, Single Output Dc-dc Converter
Manufacturer
Martek Power
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NL5077-LF
Manufacturer:
RTA
Quantity:
5 817
www.martekpower.com
1111 Knox Street
Input Voltage
Brown Out (75% of Full Load)
No Load Power Dissipation
Inrush Charge
Reflective Ripple Current
Logic Disable Current (Sink)
Logic Disable Power In
Input Ripple Rejection (120 Hz)
Input Ripple Rejection (800 Hz)
Efficiency (FL)
EMI:
Input Transient:
How to Order:
N L
Series
Total Output Power
Single Output
Industrial (I) or Military (M)
INPUT CHARACTERISTICS
INPUT CHARACTERISTICS
STABILITY
Units conform to MIL-STD-461D (on the input leads) with companion filter
50 Watts Output Power
S
NL50
INGLE OUTPUT
100HZ
3.3 Vdc Output (FL)
2 Vdc Output (FL)
0 dB
5 0
[fig. VII]*
[fig. II & III]*
Units can withstand 24V transients for up to 0.1 second
Phase
Gain
S
[fig. VIII]*
1KHZ
[fig. I]*
Torrance
FREQUENCY
M / 5
Min.
72
70
63
9
Output Voltage:
Maximum current
as stated in chart
10KHZ
P
78-85
Typ.
100
ER
0.5
12
50
40
75
69
7
1
3
CA 90502
C
HANNEL
- A - D
Options:
A- pins out side of unit
B- pins out bottom of unit
C- pins out top of unit
D- through hole inserts
I - M2.5 inserts
(STD threaded)
Max.
100KHZ
150
3.5
18
2
1
Units
Watt
Vdc
Vdc
mc
USA
μA
dB
dB
W
%
%
%
%
Set Point Accuracy
Load Regulation
Line Regulation
Ripple P-P (10 MHz)
Trim Range
Remote Sense Compensation
Overvoltage Protection (2V, 3.3V)
Overvoltage Protection (5V-15V)
Current Sharing
Transient Response (Vout 1%) Time/Overshoot
Temperature Drift
Long Term Drift
Current Limit
Short Circuit Current
Turn On Time
Logic Turn On Time
* figures on page 10
1% or 50mV, whichever is greater
Tel: +1 310 202 8820
FEA
SELECTION CHART
OUTPUT CHARACTERISTICS
FEA
SELECTION CHART
OUTPUT CHARACTERISTICS
Nominal
Voltage
Output
3.3
5.2
12
15
2
5
TURES
TURES
20-80% Load
Low Line - High Line
50-100% Load
.38 Inch Profile
Synchronization
N + 1 Redundancy
Remote Turn On (TTL)
Parallelable Operation
Output Voltage Trim Pin
Over Temperature Protection
Output Overvoltage/Overcurrent Protection
Built-In Test (Output Power Good)
100% Environmental Screening (Military
Version)
[fig. XI]*
[fig. IX]*
[fig. IV]*
Current
Output
(Amps)
9.6
4.2
3.3
10
10
10
Min.
100
105
20
sales@martekpower.com
NL50SI/3.3-A
NL50SI/5.2-A
NL50SI/12-A
NL50SI/15-A
NL50SI/2-A
NL50SI/5-A
300/250
250/200
250/200
(Industrial)
Number
0.01
0.01
Typ.
140
130
±10
125
Model
P
0.5
10
50
5
3
3
ER
[fig.V & VI]*
C
HANNEL
Max.
0.05
0.02
150
110
150
1
30
25
75
NL50SM/3.3-A
NL50SM/5.2-A
NL50SM/12-A
NL50SM/15-A
NL50SM/2-A
NL50SM/5-A
(Military)
Number
Model
%/1KHrs
μS/mV
μS/mV
μS/mV
% V
% V
% V
% V
Units
%/°C
% I
% I
% I
Vdc
mV
mV
mV
mS
mS
out
out
out
>> 2
out
out
out
out

Related parts for NL50

NL50 Summary of contents

Page 1

... CA 90502 USA Tel: +1 310 202 8820 Output Model Model Current Number Number (Amps) (Industrial) (Military) 10 NL50SI/2-A NL50SM/2-A 10 NL50SI/3.3-A NL50SM/3.3-A 10 NL50SI/5-A NL50SM/5-A 9.6 NL50SI/5.2-A NL50SM/5.2-A 4.2 NL50SI/12-A NL50SM/12-A 3.3 NL50SI/15-A NL50SM/15 HANNEL Min. Typ. Max. Units ✝ 150 mV [fig. IV]* ...

Page 2

H D IGH ENSITY ONVERTERS TEMPERA TURE CHARACTERISTICS TEMPERA TURE CHARACTERISTICS Min. Operating -55 Storage (Ambient) -55 Over Temperature Shutdown Thermal Resistance Case - Ambient ENVIRONMENT AL SCREENING - ENVIRONMENT AL SCREENING - Stabilization Bake: ...

Page 3

PERFORMANCE CHARACTERISTICS Input Voltage vs. Output Power 120% 100% 3.3V 80% 2V 60% 5V 15V 12V 40% 5. Input Voltage IV. Output Voltage Ripple V = ...

Page 4

... Less than 1.0 volt drop across the NLF50 • Does Not Require External Components • Meets Environmental Requirements of MIL-STD-810E and MIL-STD-901C • For Use With NL50 Series DC/DC Converters SPECIFICA SPECIFICA Input Voltage (maximum) Rated Output Current Isolation (Input/Output to Case) Operating Temperature Storage Temperature ...

Related keywords