3.7.48 KeyInitMode
To be able to personalize the read/write device it is necessary to enter a special mode, the
KeyInit Mode.
The password (is different from Keys or Logdata) ensures that none but authorized persons are
able to enter the KeyInitMode.
ATTENTION: After the successful execution of this command (answer sent with Operating
Mode BCC calculation) the read/write device enters the KeyInit Mode and BCC
calculation changes.
The read/write device changes BCC calculation automatically. On the host system the user is
responsible for the new BCC calculation. The C-Library provides the function
proloc_SetBCCMode ( ).
C-Function: void proloc_KeyInitMode (DWORD_T password);
Header-File: PROLIB6.H
Serial protocol:
HOST - READ/WRITE DEVICE
READ/WRITE DEVICE - HOST
Status:
0x06
0x02
Status
'K'
-11 ... EEPROM WRONG OLD DATA
-1 ... SERIAL ERROR
0 ... no error
/<---
7
BCC
PW0
The password was incorrect. The read/write device remains in Operating
Mode.
0
15 8
Password
PW1
23 16
PW2
Page 63 (104)
Rev. 1.0
31 24
PW3
-->/
BCC