SPECIFICATION
OUTPUT SPECIFICATIONS
Voltage accuracy
Voltage adjustability
Line regulation
Load regulation
Temperature coefficient
Overvoltage protection
Output power limit
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Safety ground
leakage current
PAGE 1
PM500 INPUT VOLTAGE
[ 2 YEAR WARRANTY ]
115±10VAC
220±20VAC
240±20VAC
VM500 Series only
PM529 and PM563 only
See table on facing
page for relevant models
Typical
Switch off/on
PM500, See Note 3
VM500
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SUFFIX
(NONE)
130% to 200% FL
100% to 200% FL
See tables below
Less than 3.5mA
D
K
47Hz to 400Hz
47Hz to 63Hz
±1.0% max.
6.2V typical
PM500 and VM500 SERIES
Single, dual and triple output
Recommended for new design-ins
• OVP on 5V outputs
• Split bobbin wound
• PCB mounting
• UL and CSA approved
• 115, 220 and 240VAC input
• Short circuit protection
• The VM500 Series has EN60950 approval
These encapsulated, PC-mountable linear power modules feature 23 single
output, 14 dual output and 13 triple output models for a wide variety of printed
circuit board applications. The 5V output of all models have overvoltage
crowbar protection as a standard feature. For maximum safety, all power
transformers are split bobbin wound, rather than layer wound, to give total
isolation with low coupling capacitance between primary and secondary.
Conservative design and rating of these modules results in reliable operation
and long life. Standard input voltage is 115VAC; other optional inputs are 220
and 240VAC. Most models are available in standard and alternate pin
configurations for second sourcing applications. This series includes 5 sub-
miniature modules for lower power applications where minimum circuit board
space is available.
±0.02%/°C
See table
See table
@ 50Hz
Yes
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
Case material
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Relative Humidity
Vibration
VM534D INPUT VOLTAGE
200 to 233VAC
PM series, no suffix
PM series, suffix D
PM series, suffix K
VM534D
Safety VM534D
Safety PM5xx CSA22.2-143/-154, UL478
Case A
Case B1 (incl. VM534D)
Case B2
Case B3
Case H
See Note 4
Operating amb.
Non-operating amb.
Derating, 50°C to 71°C
Cooling
Non-condensing
Free-air convection
SUFFIX
20% to 95% RH
Non-conductive
–25°C to +71°C
–25°C to +85°C
D
710,000 hours
408g (14.4oz)
635g (22.4oz)
Encapsulated
black plastic
181g (6.4oz)
40% typical
340g (12oz)
227g (8oz)
2500VAC
2500VAC
3000VAC
2.5%/°C
700VAC
IEC950
Linear

Related parts for PM529D

PM529D Summary of contents

Page 1

YEAR WARRANTY ] VM500 Series only SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS Voltage accuracy Voltage adjustability PM529 and PM563 only Line regulation Load regulation Temperature coefficient Overvoltage ...

Page 2

... PM533D B1 PM534 PM534D PM534K B1 VM534D B2 PM542 PM542D PM542K B3 PM545 PM545D PM545K B2 PM515 PM515D B3 PM516D B3 PM517D B2 PM566D B3 PM567D B3 PM568D (1) H PM529 PM529D PM529K A PM563 PM563D B1 PM536 PM536D B2 PM537D B3 PM597 PM597D PM597K B1 PM538 B1 PM505 PM505D B2 PM565 PM565D B3 PM501 PM501D PM501K B2 PM595S PM595DS B2 PM591D ...

Page 3

Single output PM500 series CASE A 1.75 (44.5) 0.60 1.20 (15.2) (30.5) 0.275 1.00 (7.1) 0.20 (25.4) (5.1) 0.20 (5.1) – OUT OUT + 0.80 TRIM (20.3) 2.25 (57.2) INSERT 4.40 THREAD 1.80 0.12 (3.0) DEEP (45. 0.20 ...

Related keywords