LPT60 Emerson Network Power, LPT60 Datasheet

no-image

LPT60

Manufacturer Part Number
LPT60
Description
Universal Input
Manufacturer
Emerson Network Power
Datasheet
Special Features
• Medical safety approvals
• Universal input
• 3" x 5" footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5V output
• Overvoltage protection
• Overload protection
• 110KHz switching frequency
• LPX60 enclosure kit available
Safety
VDE
UL
CSA
CE
LPT60-M Series
60 Watts
Medical
Total Power:
Input Voltage:
# of Outputs:
0750/EN60601-1 (IEC601)
21310-3336-0015
UL2601
E182560
CSA 22.2 No. 601.1
LR109492
Mark (LVD)
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input ra nge
Frequency
Inrush current
Input current
Efficiency
EMI
Safety ground
leakage current
Output
Maximum Power
Cross regulation
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
85-264VAC
120-300VDC
47-440Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1.5A max. (RMS) @ 115VAC
70% typical at full load
FCC Class A conducted; CISPR 22 Class A conducted
EN55022 Class A conducted;
VDE 0878 PT3 Class A conducted
<75μA max. @ 50/60 Hz, 264VAC input
60W for convection; 80W with 30CFW forced air
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 60W load, 115VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
RoHS
Embedded Power for
Business-Critical Continuity
LPT60-M Series
Rev. 06.15.07
1 of 3

Related parts for LPT60

Related keywords