ATA6871 ATMEL Corporation, ATA6871 Datasheet

no-image

ATA6871

Manufacturer Part Number
ATA6871
Description
Li-ion Battery Management Monitoring Emergency and Backup Circuit
Manufacturer
ATMEL Corporation
Datasheet
Features
Applications
Benefits
1. General Description
The ATA6871 is a battery cell monitoring circuit designed to act as an emergency,
safety, or backup circuit in Li-ion battery systems for electrical and hybrid electrical
vehicles (EV/HEV). It monitors overvoltage, undervoltage, and the cell temperature in
Li-ion batteries without the need of a microcontroller. The circuit has an advanced
self-test functionality, which checks the proper functionality of the monitoring compar-
ators as well as the communication lines. It can be used as a monitoring circuit as well
as an emergency indicator or as a backup system in Li-ion battery management sys-
tems. The ATA6871 can monitor four, five, or six battery cells. Up to 16 IC’s can be
cascaded. If one or more battery cells exceed the over or undervoltage thresholds for
longer than 2 seconds, or if the temperature input exceeds the temperature limit for
more than 2 seconds, a digital output signal is set to high.
Overvoltage Monitoring
Undervoltage Monitoring
Cell Temperature Monitoring
Self-diagnosis including
Hot Plug-in Capable
Less than 10 µA Stand-by Current
Low Cell Imbalance Current (< 10 µA)
Circuit Customization, e.g. for Over/Undervoltage Thresholds Possible for Adequate
Volumes
Cost-efficient Solution Due to Cost Optimized 30V CMOS Technology
Daisy-chainable
Package SSO28
Backup Battery-Cell Monitoring System for Li-ion Batteries
Emergency Indicator in Li-ion Batteries
Monitoring System in Li-ion Batteries
Highest Safety Level for Li-ion Battery Systems
Circuit Customization, e.g. Over and Undervoltage Thresholds, Possible for Large
Production Volumes
– Comparator Functions
– Communication Lines
– Short and Open Measuring Lines
– Each IC Monitors 6 Battery Cells
– 16 ICs (96 Cells) per String
– No Limit on Number of Strings
– Reliable Communication between Stacked ICs Due to Level Shifters with Current
Sources
Li-ion Battery
Management
Monitoring
Emergency and
Backup Circuit
ATA6871
Preliminary
www.DataSheet4U.com
9123B–AUTO–07/09

Related parts for ATA6871

Related keywords