LM3S308 Luminary Micro, Inc, LM3S308 Datasheet - Page 47

no-image

LM3S308

Manufacturer Part Number
LM3S308
Description
Lm3s308 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S308
Manufacturer:
DSP
Quantity:
648
Part Number:
LM3S308-EQN25-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-EQN25-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IGZ25-C2
Manufacturer:
AV
Quantity:
241
Company:
Part Number:
LM3S308-IGZ25-C2
Quantity:
982
Part Number:
LM3S308-IQN25
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IQN25-C2
Manufacturer:
TI
Quantity:
202
Part Number:
LM3S308-IQN25-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IQN25-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
5.2.4.1
5.2.4.2
5.3
June 04, 2008
GPIO Functionality
When the controller is reset with either a POR or RST, the JTAG port pins default to their JTAG
configurations. The default configuration includes enabling the pull-up resistors (setting GPIOPUR
to 1 for PB7 and PC[3:0]) and enabling the alternate hardware function (setting GPIOAFSEL to
1 for PB7 and PC[3:0]) on the JTAG pins.
It is possible for software to configure these pins as GPIOs after reset by writing 0s to PB7 and
PC[3:0] in the GPIOAFSEL register. If the user does not require the JTAG port for debugging or
board-level testing, this provides five more GPIOs for use in the design.
Caution – If the JTAG pins are used as GPIOs in a design, PB7 and PC2 cannot have external pull-down
resistors connected to both of them at the same time. If both pins are pulled Low during reset, the
controller has unpredictable behavior. If this happens, remove one or both of the pull-down resistors,
and apply RST or power-cycle the part.
It is possible to create a software sequence that prevents the debugger from connecting to the Stellaris
microcontroller. If the program code loaded into flash immediately changes the JTAG pins to their
GPIO functionality, the debugger may not have enough time to connect and halt the controller before
the JTAG pin functionality switches. This may lock the debugger out of the part. This can be avoided
with a software routine that restores JTAG functionality based on an external or software trigger.
ARM Serial Wire Debug (SWD)
In order to seamlessly integrate the ARM Serial Wire Debug (SWD) functionality, a serial-wire
debugger must be able to connect to the Cortex-M3 core without having to perform, or have any
knowledge of, JTAG cycles. This is accomplished with a SWD preamble that is issued before the
SWD session begins.
The preamble used to enable the SWD interface of the SWJ-DP module starts with the TAP controller
in the Test-Logic-Reset state. From here, the preamble sequences the TAP controller through the
following states: Run Test Idle, Select DR, Select IR, Capture IR, Exit1 IR, Update IR, Run Test
Idle, Select DR, Select IR, Capture IR, Exit1 IR, Update IR, Run Test Idle, Select DR, Select IR,
and Test-Logic-Reset states.
Stepping through the JTAG TAP Instruction Register (IR) load sequences of the TAP state machine
twice without shifting in a new instruction enables the SWD interface and disables the JTAG interface.
For more information on this operation and the SWD interface, see the ARM® Cortex™-M3 Technical
Reference Manual and the ARM® CoreSight Technical Reference Manual.
Because this sequence is a valid series of JTAG operations that could be issued, the ARM JTAG
TAP controller is not fully compliant to the IEEE Standard 1149.1. This is the only instance where
the ARM JTAG TAP controller does not meet full compliance with the specification. Due to the low
probability of this sequence occurring during normal operation of the TAP controller, it should not
affect normal performance of the JTAG interface.
Initialization and Configuration
After a Power-On-Reset or an external reset (RST), the JTAG pins are automatically configured for
JTAG communication. No user-defined initialization or configuration is needed. However, if the user
application changes these pins to their GPIO function, they must be configured back to their JTAG
functionality before JTAG communication can be restored. This is done by enabling the five JTAG
pins (PB7 and PC[3:0]) for their alternate function using the GPIOAFSEL register.
Preliminary
LM3S308 Microcontroller
47
®