MT8889C Mitel Semiconductor, MT8889C Datasheet - Page 11

no-image

MT8889C

Manufacturer Part Number
MT8889C
Description
Integrated DTMFTransceiver with Adaptive Micro Interface
Manufacturer
Mitel Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT8889CE
Manufacturer:
MITEL
Quantity:
4
Part Number:
MT8889CE1
Manufacturer:
ZARLINK
Quantity:
18
Part Number:
MT8889CE1
Manufacturer:
ZARLINK
Quantity:
1 007
Part Number:
MT8889CN
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT8889CS
Manufacturer:
OKI
Quantity:
5 555
Part Number:
MT8889CS
Manufacturer:
ZARLINK
Quantity:
15
Part Number:
MT8889CS
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT8889CS
Quantity:
586
Part Number:
MT8889CS1
Manufacturer:
ZARLINK
Quantity:
3 190
Part Number:
MT8889CS1
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT8889CSR1
Manufacturer:
ZARLINK
Quantity:
150
Company:
Part Number:
MT8889CSR1
Quantity:
240
Notes:
R1, R2 = 100 k 1%
R3 = 374
R4 = 3.3 k
R
C1 = 100 nF 5%
C2 = 100 nF 5%
C3 = 100 nF 10%*
X-tal = 3.579545 MHz
BIT
DTMF/CP
INPUT
DTMF
OUTPUT
b0
b1
b2
b3
L
= 10 k
TRANSMIT DATA
REGISTER EMPTY
(BURST MODE ONLY)
RECEIVE DATA REGISTER
FULL
DELAYED STEERING
1%
(min.)
10%
C1
NAME
R1
IRQ
Figure 13 - Application Circuit (Single-Ended Input)
R2
X-tal
R
L
Table 8
Interrupt has occurred. Bit one
(b1) or bit two (b2) is set.
and transmitter is ready for new
data.
Valid data is in the Receive Data
Register.
Set upon the valid detection of
the absence of a DTMF signal.
Pause duration has terminated
* Microprocessor based systems can inject undesirable noise into the supply rails.
The performance of the MT8889C/MT8889C-1 can be optimized by keeping
noise on the supply rails to a minimum. The decoupling capacitor (C3) should be
connected close to the device and ground loops should be avoided.
.
STATUS FLAG SET
MT8889C/MT8889C-1
Status Register Description
IN+
IN-
GS
VRef
VSS
OSC1
OSC2
TONE
R/W/WR
CS
IRQ/CP
DS/RD
St/GT
VDD
RS0
ESt
D3
D2
D1
D0
R3
MT8889C/MT8889C-1
Interrupt is inactive. Cleared after
Status Register is read.
Cleared after Status Register is
read or when in non-burst mode.
Cleared after Status Register is
read.
Cleared upon the detection of a
valid DTMF signal.
STATUS FLAG CLEARED
C2
V
R4
C3
DD
To P
or C
4-117

Related parts for MT8889C