Model
CPCI-204-1203
CPCI-204-1203M
48 VDC INPUT
AC INPUT
Model
DPCI-204-1203
DPCI-204-1203M
DPCI SERIES SPECIFICATIONS
AC INPUT: 90-264 Vac continuous range, 47 to 63 Hz.
POWER FACTOR: 0.99 typical at full load. Meets EN61000-3-2.
INRUSH:
CPCI : Cold start ac current is less than 27 A at 115 Vac, and 50 A
at 230 Vac. Limited by thermistor.
BROWNOUT PROTECTION: Holds regulation to 85 Vac
(30 seconds maximum)
HOLDUP TIME: 10 ms minimum after removal of power at full load.
EFFICIENCY: 70% typical.
DC INPUT: 36-72 Vdc
EFFICIENCY: 75% typical
* Note: For full output current capability on V2, V3, V4.
CPCI SERIES SPECIFICATIONS
CPCI SERIES
DPCI SERIES
Power
200 W
200 W
Power
200 W
200 W
FEATURES:
•
• Fully compliant with PICMG CompactPCI
• Current sharing and internal OR-ing diodes for N+1 redundancy
• High current 5 V and 3.3 V outputs
• CompactPCI
• Universal ac input versions with power factor correction
• 48 Vdc input versions
Connector
The CPCI series (ac input) and DPCI series (dc input) are highly reliable power supplies for Compact-
PCI systems, which are increasingly used in communications, industrial, military/aerospace, and other
applications. These power supplies offer high power density in plug-in modules that meet the require-
ments of the PICMG
These units may be used as a single power supply for a CompactPCI system, or multiple units may
be used in parallel for higher power capability as needed. In addition, all units include current sharing,
internal OR-ing diodes, and a hot plug input/output connector to offer full hot swap capability and N+1
redundancy. Also, compatible ac and dc input units offer standardization on a single power supply
series for a system mechanical configuration.
Connector
DIN “M”
DIN “M”
47 Pin
47 Pin
200 W in 3U x 8HP,
200 Watts, 48 Vdc Input
Condor D.C. Power Supplies, Inc. • 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
200 Watts, Ac Input with PFC
FAIL# SIGNAL: TTL compatible signal. Signal goes low under the following conditions:
Any of 4 outputs fail; an overtemperature shutdown; or an overvoltage shutdown.
5.0 V @ 25 A
5.0 V @ 25 A
5 V @ 25 A
5 V @ 25 A
Output 1
Output 1
®
package requires only 15 cfm of external cooling air
®
power interface specification for CompactPCI systems.
3.3 V @ 25 A
3.3 V @ 30 A
3.3 V @ 25 A
3.3V @ 30 A
Output 2
Output 2
EMI: CONDUCTED RFI
Meets FCC Part 15, Subpart J, class A;
EN55022 class A; CISPR 22 class A.
FAIL# SIGNAL: TTL compatible signal. Signal goes low
under the following conditions:
Outputs #1 or #2 fail; an overcurrent condition on outputs
#1, #2, or #3; an overtemperature shutdown; an overvolt-
age shutdown; or an ac input failure (5 ms warning before
outputs shutdown).
12 V @ 5.5 A
12 V @ 5.5 A
12 V @ 5.5 A
12 V @ 5.5 A
Output 3
Output 3
®
specifications
-12 V @ 0.5 A
-12 V @ 0.5 A
-12 V @ 0.5 A
-12 V @ 0.5 A
Output 4
Output 4
Min. Load
Min. Load
on V1*
on V1*
3.0 A
3.0 A
3.0 A
3.0 A
EXECUTIVE MEMBER
3U x 8 HP
INPUT FAULT
From V1 & V2
From V1 & V2
Max. Output
Max. Output
35 A
35 A
35 A